15” TRUE ICE
®
MACHINE INSTALL GUIDE
TEC_TM_155 REV. A
12/07/2021
Page 23 of 64
Rear wall of cut out
DO NOT INSTALL
OUTLET IN THIS AREA!
Countertop
PRIOR TO INSTALLATION
ELECTRICAL OUTLET LOCATION
To minimize the depth of the cutout opening, the
electrical outlet must be positioned as shown below.
Outlet must be flush with wall.
15” (381 mm)
opening
DRAIN CONNECTION
The True Ice
®
machine has a built-in drain pump.
WARNING: PROPER INSTALLATION REQUIRES
CONNECTION TO THE WATER SUPPLY AND
A DRAIN. THESE CONNECTIONS ARE THE
RESPONSIBILITIES OF THE INSTALLER. TR U E
WILL NOT WARRANT LEAKS OR DAMAGE
CAUSED BY IMPROPER INSTALLATION.
IMPROPER CONNECTIONS CAN RESULT IN
PERSONAL INJURY, PROPERTY DAMAGE AND
IMPROPER OPERATION. THE ICE MACHINE
MUST BE INSTALLED ACCORDING TO ALL
APPLICABLE NATIONAL, STATE AND LOCAL
CODES AND REGULATIONS.
DO NOT
reduce drain connections any smaller than
3/8 I.D.
48” (1,219.2 mm) Clear PVC drain hose, 1/2”
male NPT connector, and 1/2” hose clamp
provided by True
Using hose larger than 1/2” I.D. may require a
larger pump. A check valve may be required to
prevent excessive cycling of the drain pump.
Be sure to use the correct I.D. hose for your vertical
rise to ensure the proper flowrate and prevent drain
time alarms. For more information, see “Drain Time
Alarm” (page 38).
If the installation requires a vertical rise greater
than 84” (2,133.6 mm) include an external drain
pump to cover the additional required pumping
height. Connect the drain tube outlet from the ice
maker to the external drain pump inlet. Do not
remove the internal drain pump provided with the
ice maker. Altering the internal components in any
way will void the warranty.
DO NOT USE HOSE SMALLER THAN 3/8” I.D.
The floor drain must be large enough to
accommodate additional drainage.
The drain pump discharge line must terminate at an
open site drain.
Be sure to thoroughly inspect all connections after
installation to ensure there are no leaks. Use of
thread sealant recommended.