--iMPROPER USE OF THE GROUNDING PLUG
CAN RESULT iNA RiSK OF ELECTRIC SHOCK.
Consult a qualifiedelectrician or service person if the grounding instructionsare not com-
pletely understood, orif doubt exists as to whether the appliance isproperly grounded. Ifit
is necessary to use an extensioncord, use only a three wire extension cord that has a
three prong polarized grounding plug, and a three slot receptaclethat will accept the plug
on the appliance.The marked rating of the extensioncord should be equal to or greater
than the electrical rating ofthe appliance.
Grounding Instructions
THIS APPLIANCE MUST BE GROUNDED. In the event of an electricalshort circuit,
grounding reduces the risk ofelectric shock by providing an escape wire for the electric
current. This appliance isequipped with a cord having a grounding wire with a grounding
plug.The plug must be plugged intoan outlet that isproperly installed andgrounded.
Plug into properly installedand grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
PowerSupply
1.A short power-supplycord isprovided to reduce the risks resulting from becoming
entangled in or trippingover a longer cord.
2. Longer cord sets orextension cords are availableand may be used if care is exercised
in their use. Do not letcord hang over edge of a table or counter.
3. If a long cord orextension cord is used, (1) the marked electricalrating of thecord set
or extension cord should be at least as great as the electrical ratingof the appliance, (2)
the extension cord must be a grounding-type3-wire cord, and (3) the longer cord
should be arranged so that itwill not drape overthe counter top or table-
top where it can be pulled on by childrenor tripped over accidentally.
r.._ql
Wiring Requirements
The oven must be operated on a SEPARATE CIRCUIT.No other applianceshould share
the circuitwith the microwave oven. If itdoes, the branch circuitfuse may blow or the cir-
cuit breaker may trip.The oven must be plugged into at least a 20 AMP,120 VOLT,60 Hz
GROUNDED OUTLET.Where a standard two-prong outlet isencountered, it isthe
personal responsibilityand obligationof the consumer to have it replacedwith a properly
grounded three-prong outlet.The VOLTAGEused must be the same as specified on this
microwave oven (120 V,60 Hz). Using a higher voltage isdangerous and may result in a
fire or oven damage. Using a lowervoltage will cause slow cooking. Panasonic is NOT
responsible for any damages resultingfrom the use of the oven with any voltage other
than specified.
TV/Radio Interference
1.Operation ofthe microwave oven may cause interferenceto your radio,TV or similar
equipment.
2.When there is interference, it may be reduced or eliminated bytaking the following
measures:
(a) Placethe radio,TV, etc. away from the microwave oven as far as possible.
(b) Use a properly installed antenna to obtain strongersignal reception.
(c)Clean door and sealingsurfaces of the oven. (See Care and Cleaning ofYour
Microwave Oven)