Rinnai 6 Portable Room AC OIM
WARNING
EXPLANATION OF SYMBOLS DISPLAYED ON THE UNIT
WARNINGRiskofre/ammablematerial.Iftherefrigerantisleaked,togetherwithan
externalignitionsource,thereisapossibilityofignition.
ReadtheOPERATINGINSTRUCTIONScarefullybeforeoperation.
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and
INSTALLATIONMANUALbeforeoperation.
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION
MANUAL,andthelike.
1. Transportofequipmentcontainingammablerefrigerants
See transport regulations.
2. Markingofequipmentusingsigns
See local regulations.
3. Disposalofequipmentusingammablerefrigerants
See national regulations.
4. Storageofequipment/appliances
The storage of equipment should be in accordance with the manufacturer’s instructions.
5. Storageofpacked(unsold)equipment
Storage  package  protection  should  be  constructed  such  that  mechanical  damage  to  the  equipment  inside the 
package will not cause a leak of the refrigerant charge. The maximum number of pieces of equipment permitted to 
be stored together will be determined by local regulations.
General work area
All maintenance sta󰀨 and others working in the local area shall be instructed on the nature of work being carried 
out. Work in conned spaces shall be avoided. The area around the workspace shall be sectioned o󰀨. Ensure that 
the conditions within the area have been made safe by control of ammable material.
6. Informationonservicing
1)  Checks to the area Prior to beginning work on systems containing ammable refrigerants, safety checks 
are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the 
following precautions shall be complied with prior to conducting work on the system.
2)  Work procedure
Work shall be undertaken under a controlled procedure so as to minimise the risk of a ammable gas or vapour 
being present while the work is being performed.
3)  General work area
All maintenance sta󰀨 and others working in the local area shall be instructed on the nature of work being carried 
out. Work in conned spaces shall be avoided. The area around the workspace shall be sectioned o󰀨. Ensure that 
the conditions within the area have been made safe by control of ammable material.
4)  Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during work, to ensure the technician 
is aware of potentially ammable atmospheres. Ensure that the leak detection equipment being used is suitable for 
use with ammable refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
5)  Presence of re extinguisher
If  any  hot  work  is  to  be  conducted  on  the  refrigeration  equipment  or  any  associated  parts,  appropriate  re 
extinguishing equipment shall be available to hand. Have a dry powder or CO
2
re extinguisher adjacent to the 
charging area�
SAFETY & IMPORTANT INFORMATION