www.gaslandchef.com
3330-A Marathon Ct Charleston, SC 29418
05
1 (844) 538-7890
The rangetop should be connected to the supply line with 1/2-inch black iron pipe
or a certified flexible type stove connector. To prevent gas leaks, put an approved
sealing compound which is resistant to liquefied petroleum gases on all threaded
connections.
Important: Do not apply pressure directly to the rangetop manifold pipe when
tightening supply connections. The manifold pipe should be held securely at the
pressure regulator to prevent twisting. Hold the pressure regulator with a wrench
during the tightening of the connection, or the manifold pipe may be twisted and
split and cause a dangerous leak.
The installation of rangetops designed for manufactured (mobile) home installa-
tion must conform with the Manufactured Construction and Safety, Title 24 CFR,
Part 3280, [formerly the Federal standard for Mobile Home Construction and
Safety, Title 24, HUD (Part 280)] in the U.S.A. or C.S.A. Standard CAN/CGA
Z240.4.2 in Canada or, when such standards are not applicable, with local codes.
The installation of rangetops designed for recreational vehicle installation must
conform with state or other codes or, in the absence of such codes, with the
standard for recreational vehicles. ANSI A119.2.2–1982 in the U.S.A. or CAN/C-
GA Z240.4.2 in Canada.
The installation of appliances designed for recreational park trailers must conform
with state or other codes or, in the absence of such codes, with the standard for
recreational park trailers, ANSI A119.5.
Note: Check all piping connections in the unit for leaks. Never use an open flame
to check for gas leaks. Use a soap solution, 75% water, 25% dish washing soap.
It is possible for connections made at the factory to leak, due to vibration encoun-
tered in transportation. Make certain you have checked them all, and repair any
connections that leak.
The appliance and its individual shut-off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 psig.
The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig.