5. HEALTH AND SAFETY INFORMATION
– 9 –
The charger must be disconnected from the supply mains when removing the battery.
The battery is to be disposed of in-line with local authority procedures.
Do not use any other than the designated Draper batteries/chargers with this product.
Do not crush, open or burn the battery. Exposure to potentially harmful materials may occur.
In case of fire use CO2 or dry chemical extinguisher.
Do not expose to high temperatures >50°C. The battery may degrade at high temperatures.
Charge battery in conditions between 5°C to 30°C with the specified charger designed for
this battery.
Do not use battery if it has been stored at 5°C or less. Allow it to “normalise” at room
temperature before usage/charging.
Warning!
Leaking battery packs
The electrolyte in battery packs is corrosive. Avoid contact with the skin.
If contact is made, flush the area with running water, pat dry and seek medical attention and
advice at the earliest opportunity.
Inform medical personnel that the contaminant is a “high alkaline, corrosive liquid”.
If electrolyte comes into contact with the eyes, flush with copious amounts of water only.
Seek medical attention immediately, relaying the information above.
5.5 CONNECTION TO THE POWER SUPPLY (CHARGER)
Caution: Risk of electric shock. Do not open.
This appliance is supplied with a moulded 3 pin mains plug for your safety. The value of the fuse
fitted is marked on the pin face of the plug. Should the fuse need replacing, ensure the substitute
is of the correct rating, approved to BS1362 and ASTA or BSI Kite marked.
ASTA
BSI
The fuse cover is removable with a small plain slot screwdriver. Ensure the fuse cover is replaced
before attempting to connect the plug to an electrical outlet. If the cover is missing, a replacement
must be obtained or the plug replaced with a suitable type.
If a replacement plug is to be fitted this must be carried out by a qualified electrician.
The damaged or incomplete plug, when cut from the cable should be disabled to prevent
connection to a live electrical outlet.
This appliance is Class II
and is designed for connection to a power supply matching that detailed
on the rating label and compatible with the plug fitted.
If an extension lead is required, use an approved and compatible lead rated for this appliance.
Follow all the instructions supplied with the extension lead.
Double insulated : This product requires no earth connection as supplementary insulation
is applied to the basic insulation to protect against electric shock in the event of failure of the
basic insulation.
IMPORTANT
If using an extension lead, follow the instructions that came with your lead regarding
maximum load while cable is wound. If in doubt, ensure that the entire cable is unwound.
Using a coiled extension lead will generate heat which could melt the lead and cause a fire.