3. Fold the insulation back to expose the terminal cover.
FIGURE 15.
4. Lower Element: Lift out the tab as shown to unclip the
terminal cover from the thermostat. The terminal cover can
now be removed from the thermostat.
FIGURE 16.
5. Remove the screws from terminal 2 of the element, and
move the looped end of the wire aside.
FIGURE 17.
6. The buss bar is labeled 5500 W. Place the buss bar over
terminals 2 and 3 with the 5500 W visible. Install the extra
screw provided into terminal 3.
FIGURE 18.
7. The wire removed from terminal 2 has a looped end. It must
remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.
FIGURE 19.
8. Tighten terminals 2 and 3 to ensure proper electrical
connection.
Failure to tighten terminal screws can cause a re which can result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE.
9. Replace terminal cover on thermostat making sure that the
locking tabs on the terminal cover are in place.
Make sure the thermostat is ush against the tank, the terminal
cover is in place, and the insulation is replaced. Failure to
do so can result in DEATH, SERIOUS BODILY INJURY, OR
PROPERTY DAMAGE.
10. Replace the insulation so that it completely covers the
thermostat and element.