ROOM ABOVE (non-insulated ceiling)
ATTIC ABOVE (insulated ceiling)
B
A
Ceilng firestop from
bottom
Ceiling firestop from
top
Note:
Use same dimensional lumber for framing
ceiling firestop and joists.
Figure 8.5 Installing the Ceiling Firestop
• Installaceilingrestopwheneverchimneypenetrates
ceiling/oor.
• Mark and cut an opening in ceiling as shown in
Figure8.5.
• Frametheopeningwiththesamesizelumberusedin
theceilingjoists.
• Nailtheceilingrestoptothebottomoftheceilingjoists
whenthereisaroomabove.
• Useanatticinsulationshieldiftheceilingisinsulated.
Theceilingrestopmaythenbeattachedaboveorbelow
thejoists.
D. Install Ceiling Firestops
CAUTION! Risk of Fire! Ceiling restops must be used
whenever the chimney penetrates a ceiling/oor.
• Chase construction requires ceiling restops at each
oor or every 10 ft (3.05 m) of clear space.
• The ceiling restop slows spread of re and reduces cold
air inltration.
WARNING! Risk of Fire! DO NOT seal area between
restop opening and chimney pipe except where they
enter the attic or leave the warm air envelope of the
home (use 600° F sealant).
OutdoorLifestylesbyHearth&HomeTechnologiesInc.•4072-137RevK•10/15
Catalog #
A B
Anglein. mm in. mm
FS338 14-1/2 368 14-1/2 368 0°
FS339 14-1/2 368 18-3/8 467 15°
FS340 14-1/2 368 23 584 30°
Loading ...