9
To AVOID damaging gas, power or other underground utility lines,
contact underground utility locating companies BEFORE digging
more than 18 inches (46 cm) deep.
To prevent damage to the operator or gate, DO NOT drive the limit
(nuts) actuators on the shaft past their normal positions.
Step 1 Install the Operator
Check the national and local building codes before installation.
Install With Adjustable Rails
1. Locate and anchor two posts made of 3" (7.6 cm) outer diameter
heavy walled pipe. Posts should be parallel and square to the gate.
2. Locate electrical conduit, as required, prior to pouring concrete.
3. Slide the four 3" (7.6 cm) clamps (provided) into the rails on the
sides of the operator.
4. Slide the posts into the clamps and tighten the screws on the
clamps to secure the operator.
8.5" (21.6 cm)
27-1/4" (69.2 cm)
3" (7.6 cm) outside
diameter heavy wall
fence pipe
(Gate)
Drive and idler sprocket toward gate side
Clamp
Rail
39" (99.1 cm)
Minimum
Depth Required By
Local Codes or Below
Frost Line
12" (30.5 cm)
Minimum from
ground
Power and Control Wiring Must
Be Run In Separate Conduit
INSTALLATION