Typical System Standby Battery Current Consumption (mA)
System voltage 24V
Control board with no radios programmed 2.7 mA
One or more LiftMaster
®
remote controls programmed +1 mA
myQ
®
device or wireless dual gate programmed +2.4 mA
Expansion board +11.1 mA
Relay adapter board +11.1 mA
Per loop detector LOOPDETLM (up to 3 loop detectors can be plugged in to the expansion board) +3.8 mA
Add up current draw by feature and accessory to determine total current draw
NOTE: The use of photoelectric sensor heaters (models LMRRUL and LMTBUL) is NOT recommended in solar applications.
INSL24UL SOLAR GATE CYCLES PER DAY - 1,000 lb. gate 20 ft. travel
BATTERY
CURRENT
DRAW
(mA)
ZONE 1
(6 Hrs Sunlight/Day)
ZONE 2
(4 Hrs Sunlight/Day)
ZONE 3
(2 Hrs Sunlight/Day)
7AH
batteries
33AH
batteries
7AH
batteries
33AH
batteries
7AH
batteries
33AH
batteries
20W
SOLAR
PANEL
5
20 23 12 14
15 18 22 10 12
20 18 21 12
50 13 16
100
40W
SOLAR
PANEL
5
38 53 23 32 13
15 36 51 21 30 12
20 35 50 20 29 11
100 20 34 15
200 17
60W
SOLAR
PANEL
5
47 84 28 51 12 21
15 45 82 26 49 10 20
20 44 81 26 48 19
100 29 63 12 32
250 33
IHSL24UL SOLAR CYCLES PER DAY - 3,000 lb. gate 20 ft travel
BATTERY
CURRENT
DRAW
(mA)
ZONE 1
(6 Hrs Sunlight/Day)
ZONE 2
(4 Hrs Sunlight/Day)
ZONE 3
(2 Hrs Sunlight/Day)
7AH
batteries
33AH
batteries
7AH
batteries
33AH
batteries
7AH
batteries
33AH
batteries
20W
SOLAR
PANEL
5
11
15 10
20
50
100
40W
SOLAR
PANEL
5
18 25 11 15
15 17 24 14
20 16 23 14
100 16
200
60W
SOLAR
PANEL
5
22 39 13 24
15 21 38 12 23
20 20 38 12 22
100 13 30 15
250 15