Loading ...
Loading ...
Loading ...
Location requirements
IMPORTANT."Observe all governing codes and ordi-
nances. Have a qualified technician install the hood
insert. It isthe installer's responsibility to comply with
installation clearances specified on the model/serial
rating plate. The model/serial rating plate is located
behind the left filter on the rear wall of the hood
insert.
The range hood location should be away from strong
draft areas, such as windows, doors and strong heat-
ing vents.
Grounded electrical outlet is required.
All openings in ceiling and wall where range hood will
be installed must be sealed.
For Mobile Home Installations
The installation of this hood insert must conform to the
Manufactured Home Construction Safety Standards,
Title 24 CFR, Part 328 (formerly the Federal Standard
for Mobile Home Construction and Safety, Title 24,
HUD, Part 280) or when such standard is not appli-
cable, the standard for Manufactured Home
Installation 1982 (Manufactured Home Sites, Commu-
nities and Setups) ANSI A225.1/NFPA 501A, or latest
edition, or with local codes.
(5.1 cm)
30" (76.2 cm)
36" (91.4 cm)
291/8" (74.0 cm)
351/8" (89.2 cm)
] 0"
(25.4 cm)
23" (58.4 cm)
Serial Plate Location
Remove the grease filters.
The rating plate is located behind the filter by the
electrical box.
Loading ...
Loading ...
Loading ...