STEP 4 Final Check
When installation is complete, confirm that:
The dryer is plugged into an electrical outlet and grounded properly.
The exhaust ductwork is connected, and the joints are taped.
You have used rigid or stiff-walled flexible metal duct material, not plastic flexible duct.
The dryer is level and is sitting firmly on the floor.
The dryer starts, runs, heats, and shuts off properly.
CAUTION
The burner may not ignite initially due to air in the gas line. Allowing your dryer to operate on a heat setting
will purge the line.
Exhaust ducting guide
Ducting
1. Make sure the dryer is installed properly so the air exhausts freely.
2. Use 4-inch rigid metal ducts. Tape all joints including the dryer connection.
Never use lint-trapping screws.
3. To facilitate the exhaust, keep the ducts as straight as possible.
Cleaning
Clean all old ducts before installing the dryer, and make sure the vent flap opens and closes freely. We
recommend that you to clean the exhaust system annually or on a regular basis.
WARNING
To prevent fire, do not use plastic, thin-foil, or non-metal flexible ducts of any kind.
Do not use a poor exhaust system because it slows down the dryers performance.
Do not use excessively long ducts that have multiple elbows.
Do not use crushed or clogged venting or ducts.
DV6900B_SimpleUX_WEB_Heatpump_EN.indd 25 2022/6/23 16:28:01