Installation
English22
English
3-wire system
A B C L2 L1
D
E
A. External ground connector
B. Neutral grounding wire (white)
C. Center silver-colored terminal block
screw
D. Neutral wire (white or center wire)
E.
3
/4 (1.9 cm) UL-listed strain relief
1. Loosen or remove the screws from the center
terminal block.
2. Connect the neutral wire (white or center wire) of the
power cable to the center, silver-colored terminal
screw of the terminal block. Tighten the screws.
3. Connect the other wires to outer terminal block
screws. Tighten the screws.
4. Tighten the strain relief screws.
5. Insert the terminal block cover into the rear panel of
the dryer. Then, secure the cover with a hold-down
screw.
CAUTION
To convert from the 4-wire system to 3-wire system,
connect the ground strap to the terminal block
support to ground the dryer frame to the neutral
conductor.
Ring-type terminals are recommended. If using strap
terminals, make sure they are tightened.
Connect the power cord and check L1/L2/D (N)
voltage. If the voltage is low, it may not heat properly.
Review the “Electrical requirements” section on page
17 if needed.
DV6900B_SimpleUX_WEB_Heatpump_EN.indd 22 2022/6/23 16:28:01