1.3 INTENDED USE / USAGE PROPOSÉ
This appliance is intended to be used as a zero clearance fireplace. This unit is certified for installation in a bedroom or a
bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E unit & 1600
cubic feet for H unit). In Canada all bedroom installations require the use of wall thermostats (note: thermostats are not
allowed in the United States).
Cet appareil est destiné à être utilisé comme un foyer à dégagement zéro. This unit is certified for installation in a
bedroom or a bed sitting room where the maximum input is within 50 cubic feet per 1000 Btu/hr, (i.e. 900 cubic feet for E
unit & 1600 cubic feet for H unit). In Canada all bedroom installations require the use of wall thermostats (note:
thermostats are not allowed in the United States).
1.4 GENERAL SAFETY / SÉCURITÉ GÉNÉRALE
Maintain adequate clearances around air openings into the combustion chamber.
Respecter les distances minimales convenables autour des bouches d'air dans la chambre de combustion.
Maintain adequate accessibility clearances for servicing and proper operation.
Respecter les distances minimales d'accessibilité suffisante pour l'entretien et bon.
This appliance shall not be connected to chimney flue serving a separate solid-fuel burning appliance.
Cet appareil ne doit pas être raccordé à une cheminée desservant un autre appareil brûlant des combustibles
solides.
The appliance area must be kept clear and free from combustible materials, gasoline and other flammable liquids
and vapors.
La zone appareil doit rester clair et exempt de matériaux combustibles, essence et autres vapeurs et liquides
inflammables.
The flow of combustion and ventilation air shall not be obstructed.
Le débit de combustion et de ventilation ne doit pas être obstrué.
The combustion air supply shall be in the same pressure zone as the drafthood relief opening on an appliance
equipped with a drafthood or as the vent outlet on an appliance not equipped with a drafthood.
L'alimentation en air de combustion doit être dans la zone même pression que l'ouverture de secours hotte à air
sur un appareil équipé d'une hotte à air ou que l'évent de sortie sur un appareil n'est pas équipé d'une hotte à air.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to
inspect the appliance and to replace any part of the control system and any gas control which has been under
water.
Ne pas se servir de cet appareil s’il a été plongé dans l’eau, même partiellement. Faire inspecter l’appareil par un
technicien qualifié et remplacer toute partie du système de contrôle et toute commande qui ont été plongées dans
l’eau.