IM32I100SP Best

User Manual - Page 4

For IM32I100SP.

PDF File Manual, 60 pages, Read Online | Download pdf file

IM32I100SP photo
Loading ...
Loading ...
Loading ...
- 4 -
OPERATION
Controls
The hood is operated using the (5) push buttons located on the underside of the
hood. Fig. 1.
Ten Minute Delay
Press Blower Speed 1, Blower Speed 2, or Blower Speed 3 for two seconds when
the blower is running at the selected speed. The LED below the button will start
blinking to display the delay function. After ten minutes the blower will automatically
turn off. If you change the speed while the timer is running, the function will not
deactivate. To deactivate the function, press the button with the blinking LED for two
seconds. Note: The delay is not available for Blower Speed 4.
Filter Alarm
After 30 hours of blower operation, the grease filter alarm is activated and all of the
LED indicators will turn on. The alarm is activated when the motor is off and the
LEDs will remain on for 30 minutes. To deactivate the alarm, press any of the control
buttons for two seconds while the LEDs are on.
After 120 hours of blower operation the charcoal filter alarm is activated and all
of the LED indicators will blink, indicating the charcoal filters need to be replaced.
The alarm is activated when the motor is off and the LEDs will remain on for 30
minutes. To deactivate the alarm, press any of the control buttons for two seconds
while the LEDs are on.
HEAT SENTRY™
Your hood is equipped with a HEAT SENTRY™ thermostat. This thermostat is a
device that will turn on or speed up the blower if it senses excessive heat above
the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting - it turns blower up to HIGH speed.
When the temperature level drops to normal, the blower will return to its original
setting.
WARNING
The HEAT SENTRY™ thermostat can start the blower even if the hood is turned
OFF. When this occurs, it is impossible to turn the blower OFF with its switch.
If you must stop the blower, do it from the main electrical panel.
Lights
On/Low/
High/Off
Blower
Speed 1
Blower
Speed 2
Blower
Speed 3
Blower
Speed 4
Fig. 1
Loading ...
Loading ...
Loading ...