Craftsman 13953902D garage door opener

User Manual - Page 27

For 13953902D.

PDF File Manual, 76 pages, Download pdf file

Loading ...
Loading ...
Loading ...
ADJUSTMENT STEP 1
Adjustthe TravelLimits
Limit adjustment settings regulatethe points at which the door
will stop when moving up or down.
To operate the opener, press the Door Control push bar. Run the
opener through a complete travel cycle.
Does the door open and close completely?
Does the door stay closed and not reverse unintentionally when
fully closed?
If your door passes both of these tests, no limit adjustments are
necessaryunless the reversing test fails (Adjustment Step 3,
page 29).
Adjustment procedures are outlined below. Readthe procedures
carefully before proceeding to Adjustment Step 2. Use a
screwdriver to make limit adjustments. Runthe openerthrougha
completetravel cycleafter each adjustment.
NOTE:Repeatedoperation of the opener during adjustment
procedures may cause the motor to overheat and shut off. Simply
wait 15 minutes and try again. If anything interferes with the
door's upward travel, it will stop. If anything interferes with the
door's downward travel (including binding or unbalanced doors),
it will reverse.
Without a properly installed safety reversalsystem, persons
(particularly small children) could be SERIOUSLYINJUREDor
KILLEDby a closing garage door.
Incorrect adjustment of garagedoor travel limits will
interfere with proper operation of safety reversalsystem.
If one control (force or travel limits) is adjusted, the other
control may also need adjustment.
After ANY adjustments are made, the safety reversal system
MUST be tested. Door MUST reverse on contact with
1-1/2" (3.8 cm) high object (or 2x4 laid flat) on floor.
To prevent damageto vehicles, be sure fully open door
provides adequateclearance.
HOWAND WHENTO ADJUSTTHE LIMITS
If the door does not open completelybut opensat least
5 feet (1.5 m):
Increase up travel. Turn the UP limit adjustment screw
clockwise. Oneturn equals 2" (5 cm) of travel.
If doordoes not openat least 5 feet (1.5 m):
Adjust the UP (open) force as explained in Adjustment Step 2.
If the door does not closecompletely:
Increase down travel. Turn the down limit adjustment screw
counterclockwise. Oneturn equals 2" (5 cm) of travel.
If door still won't close completely try lengthening the door
arm (page 25) and decreasing the down limit.
If the opener reversesin fully closedposition:
Decreasedown travel. Turn the down limit adjustment screw
clockwise. Oneturn equals 2" (5 cm) of travel.
If the door reverseswhenclosingand there is no visible
interferenceto travel cycle:
If the opener lights areflashing, the Safety Reversing Sensors
are either not installed, misaligned, or obstructed. See
Troubleshooting, page21.
Test the door for binding: Pull the emergency releasehandle.
Manually open and close the door. If the door is binding or
unbalanced,call for a trained door systems technician. If the
door is balanced and not binding, adjust the DOWN(close)
force. SeeAdjustment Step 2.
0
.........
Limit Adjustment Screws
Left Side Panel
ADJUSTMENT LABEL
27
Loading ...
Loading ...
Loading ...