8
TABLE N°1
Adaption to various types of gas
Burners Gas type Pressure
(kPa)
Injector
(mm)
Mj/hr By-pass size
(mm)
Small Natural 1.00 0.90 4.00 0.30 regulated
Small ULPG 2.75 0.54 4.00 0.30
Medium Natural 1.00 1.18 7.00 0.36 regulated
Medium ULPG 2.75 0.70 7.00 0.36
Large Natural 1.00 1.55 11.50 0.52 regulated
Large ULPG 2.75 0.92 11.50 0.52
Wok Natural 1.00 1.80 14.50 0.65 regulated
Wok ULPG 2.75 1.02 14.50 0.65
Wok 2way Natural 1.00
Ex.1.80
int.0.80
17.50
Ext. 0.65 reg.
int. 0.34 reg.
Wok 2way ULPG 2.75
Ex. 1.02
int. 0.50
17.50
Ext. 0.65
int. 0.34 reg.
Oven Natural 1.00 1.95 16.50 0.62 regulated
Oven ULPG 2.75 1.10 16.50 0.62
Test the operation of the cooker before leaving
Note: These burners have no aeration adjustment.
Check correct operation of the ignitions system and operation of the regulator and operation of the burners individually and
in combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any abnormality check that
the burners are correctly located. If satisfactory performance cannot be obtained, contact Bertazzoni Group service.
Important
Before leaving instruct the owner in the use of the cooker it should be expressly noted that we cannot accept any liability for
direct or indirect damage caused by wrong connection or improper installation. When being repaired, the appliance must
always be disconnected from the mains supply; if required, notify our customer service.
TABLE N°2: GAS BURNER DIMENSION
Burner Dimension (mm)
Auxiliary Ø 50
Semi-rapid Ø 70
Rapid Ø 95
Wok Ø 125
Wok 2 ways Ø 135
SUPPORT LEGS AND BACKGUARD INSTALLATION
The cookers are supplied with four transit supports (one for each corner).
Four support legs are supplied separately and are fitted on location to the four corners of the lower support frame. Each
support leg is pushed over the relevant transit support until flush with the support frame.
Each leg is adjusted by screwing the lowe r section in or out as required for fitting to a 900mm bench height. For lower
bench tops adjust the height of the legs to 180mm so the hob is located 10mm above the horizontal combustible surface,
ref. AS/NZS 5601.