NATURAL GAS CONVERSION
TO BE INSTALLED ONLY ON OR IN A NON-
COMBUSTIBLE ENCLOSURE
Note: Recommended clearances must be maintained,
see page 4.
1.
Servicing Instructions
Appliances should be serviced at least annually and
servicing must only be carried out by a Licensed Plumber
or Authorised Person.
Clean the Burner Ports and top with a Soft Brush.
Inspect and clean all combustion air inlets, then replace
the Burner ensuring it is firmly secured.
NATURAL GAS CONVERSION ONLY TO BE DONE
BY AN AUTHORISED PERSON OR LICENSED
PLUMBER.
Improper installation, adjustment, alteration, service
or maintenance can cause injury or property damage.
Read the instructions thoroughly before installing or
servicing this equipment.
This appliance must not be installed or used indoors.
The authorised person will provide a certificate of
compliance.
An AGA approved natural gas pressure regulator
must be installed in the pipeline and be set at 1 kPa.
WARNING
4. Installation of a drip leg if required in the supply line
must conform to AS5601.
Warning: Improper installation, adjustment, alteration,
service or maintenance can cause injury or property
damage. Read the instructions thoroughly before
installing or servicing this equipment.
6. Installation of 1/8” NPT plugged tapping, accessible
for test gauge connections, is required upstream of
the gas supply connection.
5. When checking for gas leaks, do not use an open
flame. Use a soap and water solution and check for
bubbles indicating gas leakage.
3. All gas pipe connections must be sealed with a
gas pipe compound resistant to Natural Gas.
2. Check with local and state plumbing and heating
codes regarding sizing of the gas lines.
(b) Where it is not practical to install solid tube
AGA certified stainless steel braided hose can
be installed. This hose assembly must comply
with AS5601 Gas Installations, pipe sizing
tables and shall not exceed 3 metres in length.
The internal diameter of the hose must not be
less than the 10mm.
(a) A minimum pipe diameter of 15mm is required
for inlet piping. A lever operated shut-off valve
should be installed within 1 metre of the
appliance for servicing the unit.
Gas Piping
(c) Chain or wire of adequate strength must be
fixed to the appliance. Only one end to the
appliance, the other end to be securely
anchored to wall or floor. The length of the
chain or wire is not to exceed 80% of the length
of the gas assembly.
(d) Tools are required to assemble the
Conversion Kit.
2 adjustable spanners
7 mm scoket
Specification Natural Gas
Gas consumption @ 1.0kPA
Injector sizeInjector size
Main burners - 1.43 mm
Side burner - 1.90 mm
3 main burners at 8.43 MJ/h each
1 side burner at 13.7 MJ/h
Total 39.0 MJ/h