Installation Instructions
USING FLEXIBLE METAL DUCTS
If rig4d all-metal duct cannot he used, then flexible albmetal
venting can be used, but it will reduce the maximum
recommended duct length. In special installations when it is
impossible to make connection with the above recommendations,
then UI, listed clothes dryer transition duct may be used as
transition venting between the dryer and wall connection only. The
use of this ducting will affect dry time.
If flexible transition duct is necessary, the following directions must
be followed.
Use the Shortest Length Possible.
Stretch the Duct to Its Maxinmm Length.
Do Not Crush or Collapse.
Never Use 'l_cansition Duct Inside the Wall or
Inside the Dryer.
Avoid Resting the Duct on Sharp Objects.
\i_nting Must Conform to Local Buildin Codes.
!LBOWHIGHLY
):.....
ELBOWSHIGHLY
DONOTUSE
EXCESSIVE
)(
EXHAUST
CRUSH I
_ FLEXIBLE[ l
_EXHAUST I I
[_ AGAINSTI
ALCOVE OR CLOSET INSTALLATION
If your dryer is approved for installation in an alcove or
closet, it will be stated on a label on the dryer back.
The dryer MUST be vented to the outdoors. See the
EXHAUST INFORMATION section.
Minimum clearance between dryer cabinet and adjacent
walls or other surfaces is:
() in. either side
3 in. front and rear
Minimum vertical space from floor to overhead cabinets,
ceiling, etc. is 52 in.
Closet doors must be louvered or otherwise ventilated and
must contain a minimum of 60 sq. in. of open area equally
distributed. If the closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open
area equally distributed.
The closet should be vented to the outdoors to prevent gas
pocketing in case of a gas leak in the supply line.
No other fuel-burning appliance shall be installed in the
same closet with the dryer.
1 0] BATHROOM OR BEDROOM
INSTALLATION
The dryer MUST be vented to the outdoors. See
EXHAUST INFORMATI()N section 6.
The installation must conform with local codes or, in the
absence of local codes, with the NATIONAL FUEL GAS
CODE, ANSI Z223.
MOBILE OR MANUFACTURED
HOME INSTALLATION
Installation must conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY S_IANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD
FOR MOBILE HOME, NO. 50lB.
The dryer MUST be vented to the outdoors with the
termination securely fastened to the mobile home
structure. (See EXHAUST INFORMATION section 6.)
The vent MUST NOT be terminated beneath a mobile or
manufactured home.
The vent duct material MUST BE METAL.
KIT 14-D346-33 MUST be used to attach the dryer
securely to the structure.
The vent MUST NOT be connected to any other duct,
vent, or chimney.
Do not use sheet metal screws or other refastening
devices which extend into the interior of the exhaust vent.
Provide an opening with a free area of at least 25 sq. in.
tbr introduction of outside air into the dryer room.
6