TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Theairconditionerdoesnotcomeon itisnotpluggedintotheelectrical
receptacle
plugintotheelectrical
receptacle
thereisnocurrent wait
theinternalsafetydevicehastripped calltheServiceCenter
Theairconditionerworksforashort
timeonly
therearebendsorkinksintheair
exhausthose
positiontheairhosecorrectly,keepingit
asshortandfreeofcurvesaspossibleto
avoidbottlenecks
somethingispreventingtheairfrom
beingdischarged
checkandremoveanyobstacles
obstructingairdischarge
Theairconditionerworks,butdoesnot
cooltheroom
windows,doorsand/orcurtainsopened closedoors,windowsandcurtains,
bearinginmindtheTIPSFORCORRECT
USEgivenpreviously
thereareheatsourcesintheroom(oven,
hairdryer,etc)
eliminatetheheatsources
theairexhausthoseisdetachedfrom
theappliance
ttheairexhausthoseinthehousingat
thebackoftheappliance(g.1).
lterclogged cleanorreplacethelteraspreviously
described
thetechnicalspecicationofthe
applianceisnotadequatefortheroom
inwhichitislocated.
Duringoperation,thereisanunpleasant
smellintheroom
thelterisclogged cleantheltersaspreviouslydescribed
Theairconditionerdoesnotoperatefor
aboutthreeminutesafterrestartingit
preventstheappliancefrombeing
restarteduntilthreeminuteshave
elapsedsinceitwaslastturnedo
wait.Thisdelayispartofnormal
operation.
Thesymbol andoneofthe
followingmessages:HL/PF apperon
thedisplay
theappliancehasaselfdiagnosissystem
toidentifyanumberofmalfunctions.
seetheSELF-DIAGNOSISchapter