Important safeguard
• Use this appliance only as described in this
instructionmanual.
Aswithanyelectricalappliance,theinstructions
aim to cover as many situations as possible.
Cautionandcommonsenseshouldbeusedwhen
operatingandinstallingthisairconditioner.
• Thisappliancehas been manufacturedtocool
and dehumidify domestic environments and
mustnotbeusedforotherpurposes.
• It is dangerous to alter or modify the unit's
characteristicsinanyway.
• Theappliancemustbe installed in accordance
withtherelevantnationallegislation.
• Shouldrepairsbenecessary,contactthenearest
authorizedRepairServiceCenter.Unauthorized
servicingcanbedangerous.
• Theapplianceisnotintendedforusebypersons
(including children) with reduced physical,
sensory or mental capabilities, or lack of
experience and knowledge, unless they have
beengivensupervisionorinstructionconcerning
useoftheappliancebyapersonresponsiblefor
theirsafety.
Children should be supervised to ensure that
theydonotplaywiththeappliance.
• If the power cable is damaged, it must be
replacedbythemanufactureroranauthorized
technicalservicecentreinordertoavoidallrisk.
• Alwaysensuretheapplianceispluggedintoa
grounded3-prongoutlet.Ifyouhaveanydoubts
checkwithaqualiedelectrician.
• Donotuseextensioncables.
• Before cleaning or maintenance operations,
alwaysunplugtheunitfromtheoutlet.
• Donotpullonorplacestrainonthepowercord
whenmovingtheappliance.
• Theapplianceshouldnotbeinstalledwherethe
atmospheremaycontaincombustiblegases,oil
orsulphur,ornearheatsources.
• Donotresthotorheavyobjectsontheappliance.
• Cleantheltersatleastonceaweek.
• Avoidusingheatersneartheunit.
• The unit should be transported in a vertical
position.Ifthisisnotpossiblesecuretheunitat
anangle,donotlieithorizontally.
• Before transporting the unit, drain the unit.
Aftertransportation,waitatleast6hoursbefore
switchingtheuniton.
• The packaging materials can be recycled.You
are therefore recommended to place them in
the special containers for dierentiated waste
collection.
• This appliance is tted with a special safety
device.Whenthecompressorswitcheso,this
devicepreventsitfromswitchingonagainforat
least3minutes.
• WARNING: Changes or modications not
expresslyapprovedbythepartyresponsiblefor
compliance could void the user's authority to
operatetheequipment.
Specic warnings for appliances with R410A
refrigerant gas
R410ArefrigerantgasconformstoECregulationson
theenvironment.
Avoid perforating the refrigerant circuit of the
appliance.
ENVIRONMENTAL INFORMATION:
This unit contains uorinated greenhouse gases
coveredbytheKyotoProtocol.
Maintenance and disposal must be carried out by
qualiedpersonnelonly(R410A,GWP=1975).
Save these instructions
Thisproductisforhouseholdonly

5
INTRODUCTION
ThankyouforchoosingaDe’Longhiproduct.Pleasetakeafew
momentstoreadtheinstructionstoavoidrisksordamagetothe
appliance.
DESCRIPTION
Description of the appliance (see page 3 - Fig. A)
A1 airoutletgrille
A2 controlpanel
A3 handles
A4 castorwheels
A5 BioSilverlter
A6 airintakegrille
A7 airexhausthosehousing
A8 airintakegrille
A9 powercable
A10drainagehosewithcap
A11remotecontrolsignalreceiver
A12remotecontrolcompartment
Description of the accessories (see page 3 - Fig. B)
B1 wallangewithcap
B2 assembledairexhausthose
B3 windowoutlet
B4 windowbracketwithpins
B5 additionalwindowbracketwithpins
B6 waterdrainhosewithcap
B7 remotecontrol
B8 endofseasondustcover
B9 endofseasonaccessoriesbag
Electrical connection
Before plugging the appliance into the electrical receptacle,
checkthat:
• Theoutlet’s powersupplycorrespondsto thevalue indi-
catedontheratinglabelonthebackoftheappliance;
• Theoutletandelectricalcircuitareadequatefortheappli-
ance;
• Theoutletisa3-holegroundedoutlet .Ifthisisnot
thecase,youmustchooseanotheroutlet.Failuretofollow
theseimportantsafetyinstructionsabsolvesthemanufac-
turerofallliability.
If it becomes necessary, the power cable must be re-
placed by a qualied professional only.
Theinstructionsbelowwillenableyoutoprepareyouraircon-
ditionerforoperationasecientlyaspossible.Beforeuse,make
suretheairintakeandoutletgrillesareunobstructed.
USE
AIR CONDITIONING WITHOUT INSTALLATION
For optimal results set-up in a double-hung window:
1) Placethebracket inthe window sill,extendthe bracket
fullywithinthewindowframe,xthebracketbyusingthe
pinthenlowerthewindowontothebracket.(Shouldthe
windowbracketbetoolargeforthewindow.Theplastic
canbecutwithasawbyaqualiedprofessional.)
2) FittheairexhausthoseB2inthehousingatthebackofthe
appliance.Insertitasshowningure1.
3) ConnectthewindowoutletB3totheotherendoftheex-
hausthose.
4) Insertthewindowoutletendoftheexhausthoseintothe
slotofthewindowbracket(g.2).
Other set-up methods:
• Thankstothelockingpins,it’spossibletousethewindow
bracketalsoforslidingwindows.Positiontheholeofthe
bracketsotoallowacorrectinstallationoftheexhausthose
(seegure3).
1
2

6
• Ifyouhaveacasementwindow(gure4)followsteps2&
3andplacethewindowoutletB3outsidethewindowto
exhaustthehotair.
•
Ifthewindowsarelarge,usetheadditionalwindowbracket
B5
(ifprovided)tocoveryourwindowaperture,extendingit
totherequiredlength,thenblockingitwiththelockingpins
supplied(seegure5).Makesureyoudonotcoverthehole
forthewindowoutlet.
Forhelpwithinstallation,operation,andforall
accessoriesandspare/replacementparts,pleasecontact
ourtollfreecustomerservicecallcenterat:
1-800-322-3848[USonly]
1-888-335-6644[Canadaonly]
01-800-711-8805(Mexicoonly]
orlogontoourwebsiteat www.delonghi.com
SEMIPERMANENT INSTALLATION
If required, your appliance can also be installedsemi-perma-
nently(Fig.6).
min. 11,8 in
min. 30cm
min. 11,8 in
min. 30cm
Proceedasfollows:
• Drillaholeø5,25inches(134mm)inanoutsidewallor
through a window pane. Respect the dimensions and
heightoftheholegiveningure7and8.
134
Ø 5,25 in.
• FitthewallangeB1intothehole.
• FittheairexhausthoseB2 intherelevanthousinglocated
ontherearsideoftheappliance.(g.1).
• FittheendofthehoseB2 tothewallangeB1 asshownin
g.8.
• WhenthehoseB2isnotconnected,thedrilledholecanbe
closedwiththeangecapB1.
3
4
6
7
inthe
window
panel
inthewooden
kickboard
ofaFrench
window
inthewall:
youare
recommended
toinsulatethe
sectionofwall
usingsuitable
insulation.
1
3
2
5

7
MAX 39 in
MIN 14 in
NOTE: As special tools are required for installation, we
suggest you have the appliance installed by specialized
personnel.
NOTE: When installingthe air conditionersemi-permanently,
youshouldleaveadoorslightlyopenlittleas1/2“(1cm)to
guaranteecorrectventilationandroompressure.
NOTE:Keeptheairhosesasshortandfreeofcurvesaspossible
toavoidconstrictions.
8
DESCRIPTION OF THE CONTROL PANEL ( Fig. C)
C1 ON/STAND-BYbutton
C2 MODE selectionbutton(conditioning,dehumidifying,fan,
heating)
C3 Decreasetemperature/programmedoperationtimebutton
C4 Timerbutton
C5 Fanspeedselectionbutton(LOW/MED/HIGH/AUTO)
C6 Increasetemperature/programmedoperationtimebutton
C7 Air-conditioningsymbol
C8 Dehumidifyingsymbol
C9 Fansymbol
C10 Heatingsymbol
C11 Alarmsymbol
C12 Fanspeedindicator
C13 Timersymbol
C14 Settemperaturesymbol
C15 Timeindicator
C16Temperaturevalueset,programmeddelayedON/OFFtime
Note:
Afterfewsecondsofthecontrolpanelinactivity,itsbrightness
willbeautomaticallyreduced.
Wheninstand-byafterfewminutesitwillbefurtherreduced.
CONTROL PANEL
C1
C10
C2
C11C12
C14
C13C15
C3
C4
C8 C9
C6
C16
C7
C5
C

8
OPERATING FROM THE CONTROL PANEL
TURNING THE APPLIANCE ON/OFF
Before plugging the appliance check the cap on back of
the unit are correctly inserted on drainage hose A10.
Plugtheapplianceintotheelectricalreceptacle.Twolinesap-
pearonthedisplayindicatingthattheapplianceisinstand-by.
Press button(C1)toswitchtheapplianceon.
Whenturnedon,theairconditionerstartsoperatinginthesame
modeaswhenitwasturnedo.
Toturnotheappliance,pressthe button,thenunplugthe
appliance.
Note
:
Neverswitchotheappliancebyunpluggingit:always
pressthe button,waitafewminutesandthenunplug.Do-
ingso,theappliancewillrunacheckoftheoperatingconditions.
AIR CONDITIONING MODE
Idealforhotmuggyweatherwhenyouneedtocoolanddehu-
midifytheroom.Tosetthismode:
• Press repeatedly the MODE button (C2) until the
conditioning symbol is displayed: the display shows the
desiredtemperature.
• Press+(C6)or-(C3)buttonstoadjustthedesiredtem-
perature.
• Selectthefanspeedbypressingthe button(C5).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelswhile main-
tainingacomfortabletemperature.
Maximum speed:toachievethetargettempera-
tureasrapidlyaspossible.
the appliance automatically selects the
mostsuitablefanspeedinrelationtothetemperaturesetonthe
digitaldisplayandcurrentroomtemperature.
The most suitable indoor temperature for the room during the
summer varies from 75°F to 81°F (24 to 27°C). You are recom-
mended, however, not to set a temperature much below the out-
door temperature.
DEHUMIDIFYING MODE
Ideal to reduce room humidity (spring and autumn, damp
rooms,rainyperiods,etc).In dehumidifyingmode,theappli-
ance MUSTbeset-upinthesame wayasforairconditioning,
withtheairexhausthose(B2)attachedtoenablethemoisture
tobedischargedoutside.Tosetthismode:
• PressrepeatedlytheMODE buttonuntilthedehumidifying
symbolisdisplayed.
FAN MODE
Whenusingthe appliancein thismode,theair exhausthose
(B2)doesnotneedtobeconnected.
Tosetthismode:
• PressrepeatedlytheMODE buttonuntilthefansymbolis
displayed.
• Selectthefanspeedbypressingthe button(C5).
Youcanchoose:
Minimum speed:forsilentoperation.
Medium speed:reducesnoiselevelsbutstillmain-
tainsagoodlevelofcomfort.

9
Maximum speed:formaximumfanpower.
HEATING MODE
Thisisidealinspringandautumnwhenoutdoortemperatures
arenotparticularlysevere.Forthismode,theapplianceshould
bepreparedinthesamewayasforairconditioning,withthe
airexhausthose(B2)attachedtoenablethemoisturetobedis-
chargedoutside.Tosetthismode:
• PressrepeatedlytheMODE buttonuntiltheheatingsym-
bolisdisplayed.
• Press+(C3)or-(C6)buttonstoadjustthedesiredtem-
perature.
Note:
• Inthismode,fanspeedisselectedautomaticallybytheap-
plianceandcannotbesetmanually.
• Whenoperatinginverycoldrooms,theappliancedefreez-
esautomatically,momentarilyinterruptingnormalopera-
tion.“Lt“appearsonthedisplay.Duringthisoperation,it
isnormalforthenoisemadebytheappliancetochange.
• Inthismode,youmayhavetowaitafewminutesbefore
theappliancestartsgivingouthotair.
• Inthismode,thefanmayoperateforshortperiods,even
thoughthesettemperaturehasalreadybeenreached.
• Itmayhappen thatthedisplayshows“HL”alarm.Inthis
case,emptytheinternalsafetytankfollowingtheinstruc-
tionintheSection“EndofSeasonoperatons”.Attheend,
pressagainthe buttontorestoretheheatingfunction.
SETTING THE TIMER
Thetimercanbeusedtodelayappliancestartuporshutdown.
Thisavoidswasting electricity bynot operatingthe appliance
whenitisnotneeded.
How to program delayed start up
• Plugtheapplianceintotheelectricalreceptacleandturn
theunittostandby.
• Pressthetimerbutton(C4):thetimersymbol(C13)and
thenumberofhourscomeon.
• Usethe+(C6)or- (C3)buttonstosetthenumberofhours
delaybeforetheappliancecomeson.
• Afewsecondafterset,thesettingismemorised,thetimer
symbolislitandthedisplayshowsthattheapplianceisin
standby.
•
Theappli
ancewillstartworkingusingthemodepreviously
set.Theappliancecanbesettocomeonwithinthenext24
hours.
Todeletethesetting,presstwotimesthetimerbutton(C4).The
timersymbol(C13)switcheso.
How to program delayed shutdown
• Withtheairconditionieron,ineverymode,itispossibleto
setthedelayedshutdown.
• PresstheTimer(C4)button:thetimersymbol(C13)and
thehoursswitchon.
• Usethe+(C6)or- (C3)buttonstosetthenumberofhours
delaybeforetheapplianceturnso.Afewsecondafterset,
thesettingismemorised,thetimersymbolislitandthe
displayshowsthecurrentmode.
Attheendofthesettimetheapplianceautomaticallyturns
instandbymode.
Todeletethesetting,presstwotimesthetimerbutton(C4).The
timersymbol(C13)switcheso.
OPERATING FROM THE REMOTE CONTROL
USING THE REMOTE CONTROL
• Pointtheremotecontrolat thereceiver(A11)onthe air
conditioner.Theremotecontrolmustbenomorethan16
ft(5meters)awayfromtheappliance(withoutobstacles
betweentheremotecontrolandthereceiver).
• Theremotecontrolmustbehandledwithextremecare.Do
notdropitorexposeittodirectsunlightorsourcesofheat.
NOTE: Theremotecontrolcanbesafelystoredintheappropiate
compartmentA12(seegure).
MAX 16 ft
MAX 5 meters

10
DESCRIPTION OF THE REMOTE CONTROL FIG. D
D1) ON/STAND-BYbutton
D2) Increase/decreasetemperature/programmedoperation
D3) “MODE”selectionbutton
D4) Fanspeedselectionbutton
D5) Switchbutton°C/°F
D6) TIMER button
INSERTING OR REPLACING THE BATTERIES
• Removethecoverontherearoftheremotecontrol;
• ReplacetheoldbatterieswithtwonewR03“AAA”1.5Vbat-
teries,insertingthemcorrectly(seetheinstructionsinside
thebatterycompartment);
• Replacethecover.
If the remote control unit is replaced or discarded, the batter-
ies must be removed and disposed of in accordance with cur-
rent legislation as they are harmful to the environment. Do not
mix old and new batteries.
Do not mix alkaline, standard (carbon-zinc) or rechargeable
(nickel-cadmium) batteries. Do not dispose of batteries in re.
Batteries may explode or leak. If the remote control is not be
used for a certain length of time, remove the batteries.
TURNING THE APPLIANCE ON
• Plugintotheelectricalreceptacle.
• Pressthe button(D1)(whenturnedon,theaircon-
ditionerstartsoperatinginthesamemodeaswhenitwas
turnedo).
• Toswitchtheapplianceo,pressbutton (D1),then
removetheplug.
NOTE: Neverswitch theapplianceo byremovingtheplug.
Alwaysswitchitobypushingonthe buttonand
waitingfewminutesbeforeremovingtheplug.Onlyinthis
waytheappliancewillperformthestandardcheckings.
FUNCTIONS SELECTION
Thecontrolsontheremotecontrolarethesameasthoseonthe
controlpaneloftheappliance(C).Youshouldthereforereferto
the instructions in the chapter“OPERATINGFROMTHE CON-
TROLPANEL”toselectthedesiredfunctions.PressbuttonD5
toswitchthetemperaturedisplayfrom°Cto°Fandviceversa.
Note:
• Thisequipmenthasbeentestedandfoundtocomplywith
thelimitsforaClassBdigitaldevice,pursuanttopart15of
theFCCRules.Theselimitsaredesignedtoprovidereason-
ableprotectionagainstharmfulinterferenceinaresiden-
tialinstallation.
• Thisequipmentgenerates,usesandcanradiateradiofre-
quencyenergyand,ifnotinstalledandusedinaccordance
withtheinstructions,maycauseharmfulinterferenceto
radio communications. However, there is no guarantee
thatinterferencewillnotoccurinaparticularinstallation.
Ifthisequipmentdoescauseharmfulinterferencetoradio
ortelevisionreception,whichcanbedeterminedbyturn-
ingtheequipmentoandon,theuserisencouragedtotry
tocorrecttheinterferencebyoneormoreofthefollowing
measures:
-Reorientorrelocatethereceivingantenna.
- Increase the separation between the equipment and
receiver.
- Connecttheequipmentintoanoutletonacircuitdier-
entfromthattowhichthereceiverisconnected.
- Consultthedealeroranexperiencedradio/TVtechnician
forhelp.
Changes ormodications notexpresslyapprovedby the
partyresponsibleforcompliancecouldvoidtheuser’sau-
thoritytooperatetheequipment.
• Thisdevicecomplies with Part 15 oftheFCCRules. Op-
erationissubjecttothefollowingtwoconditions:(1)this
device maynot cause harmful interference,and(2) this
device must accept any interference received, including
interferencethatmaycauseundesiredoperation.
• ThisClassBdigitalapparatuscomplieswithCanadianCAN
ICES-3(B)/NMB-3(B).
D1
D5
D2
D6
D4
D3
D2
D

11
SELFDIAGNOSIS
Theappliancehasaselfdiagnosissystemtoidentifyanumberofmalfunctions.
Errormessagesaredisplayedontheappliancedisplay.
IF ... IS DISPLAYED,
“LowTemperature”
(frostprevention)
..WHAT SHOULD I DO?
Theapplianceisttedwithafrostprotec-
tiondevicetoavoidexcessiveformationof
ice.The appliancestarts up againauto-
matically when the defrosting process is
completed.
IF ... IS DISPLAYED,
ProbeFailure
(Probedamaged)
..WHAT SHOULD I DO?
Ifthisisdisplayed,contactyourlocalau-
thorizedservicecenter.
IF ... IS DISPLAYED,
“HighLevel”
(Internaltrayfull)
..WHAT SHOULD I DO?
Empty theinternal safety tankfollowing
the instructions in the section “End of
season operations”. If HL alarm reoccurs
frequentely in Air Conditioning, Dehu-
midifyingorHeatingmode, contactyour
localauthorizedservicecenter.
TIPS FOR CORRECT USE
Toensureoptimalresultsfromyourairconditioner,followthese
recommendations:
• closethewindowsanddoorsintheroomtobeaircondi-
tioned.When installingtheair conditionersemi-perma-
nently,youshouldleaveadoorslightlyopen(aslittleas
1/2inch(1cm))toguaranteeproperventilation.
Closedoorsandwindows
• Neverusetheapplianceinverydamprooms(laundriesfor
example).
• Protecttheroomfromdirectexposuretothesunbypar-
tiallyclosingcurtainsand/orblindstomaketheappliance
muchmoreeconomicaltorun.
Closeblindsorcurtains
• Neverusetheapplianceoutdoors.
•
Makesuretherearenoheatsourcesintheroom.
• makesuretheairconditionerisstandingonalevelsurface.
donotcovertheappliance
• Neverrestobjectsofanykindontheairconditioner.
• Neverobstructtheairintakeoroutletgrilles.

12
CLEANING
Before cleaning or maintenance, turn the appliance o by
pressingthe button,thenunplugfromelectricalrecep-
tacle.
CLEANING THE CABINET
Youshouldcleantheappliancewithaslightlydampcloththen
drywithadrycloth.Forsafetyreasons,neverwashtheaircon-
ditionerwithwater.
Precautions
Never use petrol, alcohol or solvents to clean the appliance.
Neversprayinsecticideliquidsorsimilar.
CLEANING THE BIO SILVER AIR FILTER
Ifthelterisdirty,aircirculationiscompromisedandtheef-
ciency of the dehumidifying and air purifying functions de-
creases.
Itisthereforegoodpracticetocleanthelteratregularinter-
vals.Thefrequencydependsonthedurationandconditionsof
operation.
Iftheunitisusedconstantlyorsystematically,youarerecom-
mendedtocleanthelteronceaweek.
Thelterishousedintheintakegrille.
Tocleanthelter,extractasshowning.9.
Useavacuumcleanertoremovethedustcollectedonthelter.
Ifitisverydirty,immerseinwarmwaterandrinseanumber
oftimes.Thewatershouldneverbehotterthan104°F(40°C).
After washing the lter, allow it to dry completely before
repositioningit.
TheBioSilverlterhelpscapturedustandpollenandhelpsre-
ducethegrowthofbacteriaandmoldonthelter.
START OF SEASON CHECKS
Makesurethepowercableandplug areundamagedandthe
groundconnectionisecient.
Followtheinstallationinstructionsprecisely.
END OF SEASON OPERATIONS
Todrainallwaterfromthecircuit,removethecapA10fromthe
drainageonthebackoftheapplianceandallowthewaterto
drainoutintoabasin(g.10).
Tofacilitatethisoperation,atthestartoftheseason,it’spossi-
bletoapplythewaterdrainhosewithcapB6.
Inordertoproperlystoragetheapplianceattheendofthesea-
son,wesuggestyoucoveritwith thesuppliedendofseason
dustcoverB8andyouputtheaccessoriesintherelevant
endofseasonaccessoriesbagB9.
Whentheapplianceisempty,replacethecaps.
Cleanthelteranddrythoroughlybeforeputtingback.
TECHNICAL SPECIFICATIONS
Powersupplyvoltage seeratinglabel
Max.absorbedpower
duringairconditioning “
Refrigerant “
Coolingcapacity “
LIMIT CONDITIONS
Roomtemperatureforairconditioning
(withfansatmaximumspeed) 64÷104°F18÷40°C
10
9

13
Transport, lling, cleaning, recovery and disposal of
refrigerant should be performed by a technical service
centre appointed by the manufacturer only.
The appliance should be disposed of by a specialist centre
appointed by the manufacturer only.
TO AVOID DAMAGE TO THE UNIT:
NEVERTRANSPORTORTURNTHEAPPLIANCEUPSIDEDOWNOR
ONITSSIDE.IFTHISOCCURS,WAIT6 HOURSBEFORETURNING
THEAPPLIANCEON,24HOURSISRECOMMENDED.Aftertheunit
hasbeenonitsside,oilneedstoreturntothecompressortoen-
sureproperfunction.Withoutallowingtheunitthistime(6-24
hours)theunitmayfunctionforonlyashorttime,andthenthe
compressorwillbreakdownfromlackofoil.
ELECTRICAL CONNECTION
Thisapplianceisequippedwitha3pronggroundedplug.The
plugmustbeconnectedintoanoutletthatisproperlyinstalled
andgroundedintheaccordancewithalllocalcodesandordi-
nances.Donot modify the plug providedwith the appliance.
Ifit willnottthe outlet,havea properoutlet installed bya
qualiedelectricianorrelocatetheunittoaproperoutlet.Ifthe
householdelectricalsupplydoesnotmeettheabovespecica-
tions,orifyouarenotsureyourhomehasaneectiveelectrical
ground,haveaqualiedelectricianoryourlocalelectricalutility
companycheckitandcorrectanyproblems.
SAFETY PLUG
Theapplianceisttedwithasafetyplugtoprotectthepower
cable.
Ifpoweriscuto,unplug fromtheoutletandmakesurethe
powercableisundamaged.
Ifthecableisdamaged,calltheservicecenterimmediately.
Ifpowercutsofrequentlyandthepowercableisundamaged,
contactaqualiedelectrician.
OPERATION OF THE SAFETY PLUG
Ifthesafetydeviceincorporatedintheplugtripsand cutso
thepowersupply,checkthatthepowercableandplugarenot
damaged.
Ifthepowercableisundamaged,torestoreoperationpressthe
"RESET"button.
Toverifycorrectoperationoftheplug,pressthe"TEST"button
periodicallyandmakesuretheappliancedisconnects.Ifthisis
notthecase,contacttheservicecenter.
Torestoreoperation,pressthe"RESET"button.

14
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
Theairconditionerdoesnotcomeon itisnotpluggedintotheelectrical
receptacle
plugintotheelectrical
receptacle
thereisnocurrent wait
theinternalsafetydevicehastripped calltheServiceCenter
Theairconditionerworksforashort
timeonly
therearebendsorkinksintheair
exhausthose
positiontheairhosecorrectly,keepingit
asshortandfreeofcurvesaspossibleto
avoidbottlenecks
somethingispreventingtheairfrom
beingdischarged
checkandremoveanyobstacles
obstructingairdischarge
Theairconditionerworks,butdoesnot
cooltheroom
windows,doorsand/orcurtainsopened closedoors,windowsandcurtains,
bearinginmindthe“TIPSFORCORRECT
USE”givenpreviously
thereareheatsourcesintheroom(oven,
hairdryer,etc)
eliminatetheheatsources
theairexhausthoseisdetachedfrom
theappliance
ttheairexhausthoseinthehousingat
thebackoftheappliance(g.1).
lterclogged cleanorreplacethelteraspreviously
described
thetechnicalspecicationofthe
applianceisnotadequatefortheroom
inwhichitislocated.
Duringoperation,thereisanunpleasant
smellintheroom
thelterisclogged cleantheltersaspreviouslydescribed
Theairconditionerdoesnotoperatefor
aboutthreeminutesafterrestartingit
preventstheappliancefrombeing
restarteduntilthreeminuteshave
elapsedsinceitwaslastturnedo
wait.Thisdelayispartofnormal
operation.
Thesymbol andoneofthe
followingmessages:HL/PF apperon
thedisplay
theappliancehasaselfdiagnosissystem
toidentifyanumberofmalfunctions.
seetheSELF-DIAGNOSISchapter

15
De’LonghiisthedistributorofKenwoodhomeappliances.
This warranty applies to all home appliances with De’Longhi or Kenwood brand names
LIMITED WARRANTY
WewarranteachDe’LonghiAIRCONDITIONERtobefreefromdefectsinmaterialandworkmanship.Fromthepurchasedate,our
obligationunderthiswarrantyistoprovidetwo(2)yearfreepartsandlaborontheentireAIRCONDITIONER,withanadditionalfour
(4)yearsfreeonanypartofthesealedsystemconsistingofthecompressor,evaporator,condenserandfactoryconnectedrefrigerant
tubing.Laborandallotherpartsduringtheadditionalfour(4)yearwarrantyaretobepaidbytheowner.AllAIRCONDITIONERSin
needofrepairaretobeshippedtoanauthorizedDe’Longhiservicecenterattheowner’sexpense,andDe’Longhiwillthenincurthe
returnshippingcosts.Aftertherstsix(6)yearsofownership,allexpenses(allparts,laborandshipping)aretobepaidbytheowner
oftheunit.ThiswarrantyshallapplyonlyiftheAIRCONDITIONERisusedinaccordancewiththefactorydirectionsthataccompanyit,
andonanAlternatingCurrent(AC)circuit.Thiswarrantyisinlieuofallotherwarrantiesandrepresentations,expressedorimplied,
andallotherobligationsorliabilitiesonourpart.Wedonotauthorizeanyotherpersonorcompanytoassumeforusanyliabilityin
connectionwiththesaleoruseofourAIRCONDITIONER.ThiswarrantyshallnotapplytoanyAIRCONDITIONERthathasbeenrepaired
oralteredoutsideourfactorynorshallitapplytoanyAIRCONDITIONERthathasbeensubjectedtomisuse,negligenceoraccidents.
Ifrepairsbecomenecessary,seecontactinformationbelow:
U.S. Residents:
Pleasecontactourtollfreehotlineat 1-800-322-3848
orlogontoourwebsiteatwww.delonghi.com
CANADA Residents:
Pleasecontactourtollfreehotlineat1-888-335-6644
orlogontoourwebsiteatwww.delonghi.com
MEXICO Residents:
Pleasecontactourtollfreehotlineat01-800-711-8805
orlogontoourwebsiteatwww.delonghi.com
Theabovewarrantyisinlieuofallotherexpresswarrantiesandrepresentations.Allimplied
warrantiesarelimitedtotheapplicablewarrantyperiodsetforthabove.Thislimitationdoesnotapplyifyouenterintoanextended
warrantywith De’Longhi.Somestates/countriesdo not allow limitations on how long an implied warranty lasts, so the above
exclusionsmaynotapplytoyou.De’Longhidoesnotauthorizeanyotherpersonorcompanytoassumeforitanyliabilityin
connectionwiththesaleoruseofitsappliance.
How does country law apply?