14. Technical Data
This cooker is designed for use on Natural Gas, although a conversion for LP (LPG X Propane (2.54 kPa)) gas is included.
INSTALLER: Please leave these instructions with the user. DATA BADGE LOCATION: Cooker back, serial number repeater
badge below oven door opening. COUNTRY OF DESTINATION: Australia.
Pressures
Gas (Rp ½ at rear right-hand side) Electric
Supply Pressure
at the inlet to appliance regulator
230/400 V 50 Hz
Natural Gas 1.13 kPa
Propane 2.75 kPa
Operating Pressure
at appliance test point
Natural Gas 1 kPa
Propane 2.54 kPa
Dimensions
Model Elise 90 Dual Fuel
Overall height minimum 910 mm maximum 935
mm
Overall width 900 mm
Overall depth 598
mm excluding handles, 650 mm including handles
Minimum height above the hotplate 650 mm
Hotplate Ratings
BSI Evo 1 Type Burners Australia
Burner Type
Bypass
Screw*
Natural Gas 1.0 kPa Propane 2.54 kPa
Input
Injector
Input
Injector
Marking Size Ø Marking Size Ø
Wok 75 15.2 MJ/h-
1
198 1.93 mm 15.0 MJ/h-
1
111 1.07 mm
Rapide / Large 41 12.3 MJ/h-
1
165 1.65 mm 12.0 MJ/h-
1
89 0.96 mm
Semi Rapide / Medium 33 6.2 MJ/h-
1
115 1.15 mm 6.2 MJ/h-
1
67 0.68 mm
Auxillary / Small 25 3.7 MJ/h-
1
92 0.92 mm 3.3 MJ/h-
1
45 0.50 mm
* The valves in this cooker are tted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural Gas. For LPG conversion the
bypass screws must be screwed all the way down.
Oven Efficiencies
Ovens
Main Oven Tall Oven
Multifunction Forced Air Convection
Maximum power output @ 230 V 50 Hz 2.5 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.88kWh 0.83kWh
Usable volume (litres) 79 67
Size Large Large
Time to cook standard load 41 minutes 49 minutes
Surface area of the grid 1400cm
2
790cm
2
Grill 2.3 kW
Maximum total electrical load at 230 V
(approximate total including oven lights, oven fan, etc.): 7.4 kW.