INSTALLATION
Check the appliance is electrically safe and gas sound when you have nished.
Pressure Testing
The pressure test point is accessible on the inlet pipe at the
rear. Remove the test nipple screw and t a pressure gauge to
the test point. Turn on and light two of the hotplate burners.
For Natural Gas ranges the operating pressure should be
1 kPa.
For Propane X ranges the operating pressure should be
2.54 kPa.Electrical Connection
This appliance must be installed by a qualied electrician
to comply with with current AS/NZS 3000 Wiring Rules and
regulations in force.
Make sure that the mains characteristics (voltage, nominal,
power, etc.) match the ratings indicated on the data plate
axed to the range.
The range is preset for a single-phase earthed electrical
connection. It is essential to install a multi-pole circuit breaker
that completely disconnects the appliance from the mains,
with a minimum contact break distance of 3 mm.
n
WARNING: THIS APPLIANCE MUST BE EARTHED.
The appliance must be connected to an ecient earthing
circuit. If the electricity network is not equipped with an
earth connection, then it must be installed separately in
compliance with local regulations.
Earthing is a safety measure required by law, and must be
performed with particular care by a qualied technician, who
must also check that the electricity supply characteristics are
correct.
See the Technical Data section for information on the total
electrical load of the appliance. The cable size used should be
suitable for this load and comply with all local requirements
(i.e. PVC Insulated cable IEC 60227 – code 53 for ordinary
cables).
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type (Fig. 9.13 and Fig. 9.14). Check that the links are
correctly tted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
An isolation switch shall be provided and mounted near the
range, in a readily accessible position, in compliance with AS/
NZS 3000 and/or AS/NZS 5601 as applicable for the appliance
conguration.
Note: The marking for the rated current of the fuse protecting
a socket should be placed on or near the socket outlet.
ArtNo.132-0001 - 1 phase 240Vac 50Hz
1-phase 230 V
AC
50 Hz
Fig. 9.13
Fig. 9.14
Current Operated Earth Leakage Breakers
The combined use of your range and other domestic
appliances may cause nuisance tripping, so we recommend
that the range is protected on an individual RCD (Residual
Current Device) or RCBO (Residual Current Breaker with
Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.