Smeg SO6604S4PNR Steam100 Pro Galileo Oven 60cm

User Manual - Page 52

For SO6604S4PNR.

PDF File Manual, 59 pages, Download pdf file

Loading ...
Loading ...
Loading ...
CLEANING AND MAINTENANCE - 117914779723/A
e
3. Place the jug (or container) on the open
door.
4. Remove the loading wand from its holder.
To remove the loading wand, press on the
front of the wand until the spring contracts,
then release.
or
Touch the WAND button on the
display (positioned in the lower area ).
5. Place the end of the tube at the bottom of
the jug (or container).
6. Press the start button to start filling the
appliance reservoir with water.
7. Touch the CONFIRM button to confirm
that you have finished filling the reservoir.
The appliance starts the function using the
parameters set.
Cleaning the water circuit
When cleaning the reservoir and the
hydraulic circuit, leave the jug on the door
open with the loading wand inside. The
appliance cyclically discharges certain
quantities of water used for cleaning.
During this process, the overflowing of water
inside the oven cavity is not intended as a
malfunction, rather it is part of the rinsing
procedure.
End of water circuit cleaning
8. After completion of the cleaning process the
request to drain the water is shown on the
display.
9. Clean and dry any residual water inside the
oven cavity.
Reservoir draining
10.Open the door
11.Place a jug or container on the open door.
12.Remove the loading wand from its holder.
13. Press the START button to start draining
the water into the jug (or container).
14.Wait for the end of the drain flow.
When complete, the display will indicate that
the residual water removal process is complete.
The jug (or container) with the water
must have a gross weight lower than 5
kg.
Pay attention to the distance to be
maintained so as not to be hit by the
wand projection.
It is recommended to carry out the
cleaning process of the reservoir and
the water circuit a couple of times.
Loading ...
Loading ...
Loading ...