KNOW YOUR GENERATOR
Read the owner's manual and safety rules before operating your generator.
Compare the illustrations with your generator to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
FuelTank
Circuit Breakers "_
Choke Lever
12 Volt DC 10 Amp
Receptacle
Idle Control
Switch
120 Volt AC, 30 Amp
Receptacle
Run/Stop
Switch
Cleaner
120/240 Volt AC, 30 Amp
Receptacle
Engine
120 Volt AC, 20 Amp"
Receptacles
240 Volt AC, 50 Amp
Receptacle
120/240 Volt AC, 30 Amp Receptacle -- May be
used to supply electrical power for the operation of
120 and/or 240 Volt at 30 Amp AC, single phase,
60 Hz electrical lighting, appliance, tool and motor
loads.
120 Volt AC, 30 Amp Receptacle -- May be used to
supply electrical power for the operation of 120 Volt at
30 Amp AC, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
120 Volt AC, 20 Amp Receptacles -- May be used
to supply electrical power for the operation of 120 Volt
at 20 Amp AC, single phase, 60 Hz electrical lighting,
appliance, tool and motor loads.
240 Volt AC, 50 Amp Receptacle -- May be used to
supply electrical power for the operation of 240 Volt at
31.25 Amp AC, single phase, 60 Hz electrical loads.
12 Volt DC, 10 Amp Receptacle --This receptacle
allows you to recharge a 12 Volt automotive or utility
style storage battery with the charge cables provided.
15 H.P. Engine -- Provides the power needed to
generate 7,500 watts of AC output.
Air Cleaner -- Filters intake air as it is drawn into the
engine.
Circuit Breakers (AC) -- Circuit breakers are
provided for most receptacles to protect the generator
against electrical overload. Breakers are "push to
reset" type.
Choke Lever- Used when starting a cold engine.
Fuel Tank -- Tank holds 5 U.S. gallons of automotive
unleaded gasoline.
Idle Control Switch -- The idle control runs the
engine at normal (high) speeds when there is a load
present and runs the engine at idle (low) speeds when
a load is not present. This feature greatly improves
fuel economy, extends the life of the engine, and
reduces engine noise.
Run/Stop Switch -- Must be in "Run" position to start
engine. Set to "Stop" to stop a running engine.