PKM MW700-17UB2 Stand Unterbau Mikrowelle 17 Liter

User Manual - Page 41

For MW700-17UB2.

PDF File Manual, 62 pages, Read Online | Download pdf file

MW700-17UB2 photo
Loading ...
Loading ...
Loading ...
~ 41 ~
2.1 Installation instructions
IMPORTANT INFORMATION!
1. The installation should be carried out by a qualified professional.
2. Please keep all accessories supplied with the appliance in a safe place.
3. Remove all items from the cupboard and all fragile items from the adjacent
cabinets completely.
4. The minimum installation height is 850 mm.
5. The cupboard the appliance is installed in must meet the following conditions:
the plate provided for the installation of the appliance (installation plate) must
be 16 - 20 mm thick.
the height of the cupboard must be at least 300 mm.
the width of the cupboard must be 600 mm.
the depth of the cupboard must be at least 333 mm.
the cupboard must not have any cracks, chipping or other damages. All
connections of the cabinet must be stable.
the plate provided for the installation of the appliance (installation plate) must
be designed to hold a load of at least 22 kg.
6. The cupboard the appliance is installed in must be anchored in the wall firmly
with at least 2 screws; this wall mounting must be stable and secure.
7. Never cover the ventilation openings and air inlet points.
8. A safety socket must be near of the appliance.
WARNING! The appliance must not be installed under cabinets which
are equipped with a light strip.