Designer Series Direct Vent Gas Fireplace

 
Conversion Cover Missing One RED (1 time)
Spark Fail Two RED (1 time)
No Sensor Signal Three RED (1 time)
Pilot Lockout - trial One GREEN, every 2 sec. (until manual reset)
Pilot Lockout - ame loss One RED-GREEN, every 2 sec. (until manual reset)
Low Battery One RED, every 10s (continuously)
No or Low Thermopile Power Two RED, every 10s (continuously)
Learning GREEN Flashes, every 1 sec. (for 10 sec.)
AC Power On GREEN solid
Pressure Switch Failure One RED every 2 sec. (until manual reset)
Power Vent Only


1. Turn on the master switch and wait for a beep.
2. Press the ON button on the Command Center or turn
on wall switch. Pilot will light and burner will come on
High setting or last memory setting (See Turning Off
Fireplace below). For memory feature.

1. If the pilot doesn’t light after sparking for 30 seconds,
pilot trial lockout happens. The LED on the Command
Center ashes Green once every 2 seconds, until re-
set.
2. If the pilot ame is lost during normal operation, the
system will try three (3) times to relight after three (3)
failures, ame loss lockout happens. The LED on the
Command Center ashes Red-Green once every 2
seconds, until reset.
3. Turning the master switch on the Command Center to
the off position, then ON again will reset the system.

1. Press the ON button (on the Command Center) once to
turn on the main burner with maximum ame height.
2. Press the OFF button to decrease ame height. The rst
two presses will decrease the ame height to medium
and low.

The Command Center has a self-diagnostic LED enabling
you to troubleshoot problems and potentially avoid a
service call. Please refer to the charts below for indicator
reference.
 
Power Up Flip the master switch to the ON ("_") position to power up the system
Fireplace ON Press the ON button on the Command Center or turn on wall switch to turn the replace on
Fireplace OFF Flip the master switch to the OFF ("o") position OR press the OFF button 3
times OR for Memory Off, hold the OFF button 3 seconds, or turn off wall switch
Flame Height Up Press the ON button once to turn on the replace with maximum ame height
Flame Height Down Press the OFF button to lower the ame height to Medium and Low
3. The third press on OFF will turn off the main burner. In
standing pilot conguration, the pilot will stay; in inter-
mittent pilot conguration, the pilot will be shut off.

There are three ways to turn the replace off.
1. Flip the master switch to the off (“O”) position. (This will
turn the entire system OFF.)
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds or by
turning off the wall switch. These two commands of
OFF are (Memory Off) the system will remember all last
settings before turning off. The next time the replace is
turned on, all settings will resume. To reset, change to
the desired settings and shut off by using the Memory
Off commands and the system will be reset to those
new settings.

The following functions are available on the Command
Center.