User Manual - Page 150

For VSXLX305.

Loading ...
Loading ...
Loading ...
150
Setup
Measuring with Dirac Live
Use the Pioneer Remote App to use Dirac Live to take measurements. Use the
most recent version. Note that you cannot make settings using operations on
this unit. Refer to "Pioneer Remote App" ( p153) for information about the
app. Also have a tripod ready to set up the speaker setup microphone.
Calibration takes about 20 minutes to be completed.
Dirac Live
®
is an advanced room correction technology developed by Dirac
Research. As one of the most advanced room correction technology available
on the market, Dirac Live helps listeners to correct for one of the weakest
components in the audio chain: the listening room. Dirac Live not only corrects
the frequency response, but also the impulse response of the loudspeakers in a
room, yielding improved imaging and timbre, better clarity, tighter bass, and less
early reections, as well as reduced resonances and room modes.
1. Select "Start Dirac Live" in the "Dirac Live" screen, then press ENTER.
2. Connect the supplied Speaker Setup microphone to the SETUP MIC jack on
the main unit.
SETUP MIC
3. When you start the Pioneer Remote App, a screen automatically appears to
guide you through measurement, so tap "Start".
If the guidance screen does not automatically appear, after tapping this
unit when it appears on the screen, tap " " at the top left of the screen
and select "Dirac Live".
4. Tap "Next", conrm that the displayed speaker conguration is correct, then
tap "Next".
If the number of speaker channels set in "1.Speaker Setup" in Initial Setup
is different to the number of connected speaker channels, an error is
displayed and measurement cannot be performed.
5. Select the method of measurement. There are two methods of measuring to
choose from; "Quick" which measures 3 locations; at the listening position
and to the left and right of the listening position; and "Full" which measures 9
positions including the listening position. Tap the method you prefer.
"Quick": Set up the microphone at ear height in the listening position for
measurement. Next measure by setting up the microphone between 50 and
100 cm away to the left and right of the listening position.
"Full": Set up the microphone at ear height in the listening position for
measurement. Next, measure in 8 positions to the front, back, left, right, etc.,
centered on the listening position. Measure by setting up the microphone
in each of these positions, between 50 and 100 cm away from the listening
position.
Quick Full
The illustration shows an image.
6. The guidance about outputting the test tone is displayed. Refer to the
illustration to set up the speaker setup microphone in the listening position.
Follow the on-screen instructions to measure.
Measurement may not be possible if the test tone is too loud or too soft.
Tap "Level Adjust" to adjust the volume of the test tone.
Loading ...
Loading ...
Loading ...