48 TROUBLESHOOTING
Icemakerisnot
makingenough
ice(continued)
Doorsareopenedoftenorfor
longperiodsoftime
Dispensingwafer
slowly
Doorsarenotclosed
completely
Thetemperaturesettingforthe
freezeristoowarm
Waterfilterhasbeenexhausted
Reverse osmosis filtration
system is used
Low house wafer supply
pressure.
If the doors of the unit are opened often, ambient
air will warm the refrigerator which will prevent
the unit from maintaining the set temperature
Lowering the refrigerator temperature can help,
as well as not opening the doors as frequently
If the doors are not properly dosed, ice
production will be affected, See the Doors will
not close completely or pop open section in Parts
& Features Troubleshooting for more information
The recommended temperature for the freezer
compartment for normal ice production is O°F (-18°C)
If the freezer temperature is warmer, ice production
will be affected
It is recommended that you replace the wafer filter:
Approximately every six months.
When the water filter indicator turns on
When the water dispenser output decreases
When the ice cubes are smaller than normal
Reverse osmosis filtration systems can reduce
the water pressure below the minimum amount
and result in icemaker issues
If the problem persists, it may be necessary to
contact a plumber.
The wafer pressure must be between 20 and 120
psi (140 and 830 kPa) on models without a wafer
filter and between 40 and 120 psi (280 and 830
kPa) on models with a water filter
If the problem persists, it may be necessary to
contact a plumber.