Smeg SAIG3953B 90cm Gas / Induction Classic Natural Gas Cooktop

User Manual - Page 41

For SAIG3953B.

PDF File Manual, 46 pages, Read Online | Download pdf file

SAIG3953B photo
Loading ...
Loading ...
Loading ...
Installation
43
EN
5. Unscrew the 6 screws that hold the glass
hob top to the casing (see the figures
below for their location).
(seen from below)
90 cm
6. Remove the glass hob top.
Replacing the nozzles
1. Unscrew screw A and push air regulator
B as far as it will go.
2. Use a spanner to remove the nozzles C
and install the new ones for the required
gas supply, following the indications
given in the relevant table (see “Burner
and nozzle specifications tables”).
3. Adjust the air flow by moving the air
regulator B to obtain the distance D
given in the corresponding table (see
“Burner and nozzle specifications
tables”).
4. After adjusting each burner, reassemble
the appliance correctly.
Adjusting the minimum setting for natural
or town gas
1. Light the burner and turn it to the minimum
position.
2. Extract the gas cock knob and turn the
adjustment screw next to the gas cock
spindle (depending on the model) until
the correct minimum flame is achieved.
3. Refit the knob and verify that the burner
flame is stable.
4. Turn the knob rapidly from the maximum
to the minimum setting: The flame should
not go out.
The nozzle tightening torque must
be no more than 3 Nm.
Loading ...