Cabinet Requirements
VENTILATION
This appliance is only intended to be fully fitted in a kitchen.
This appliance is not designed to be used as a tabletop appliance or inside a
cupboard.
The fitted cabinet must not have a back wall behind the appliance.
A gap of at least 1 3/4” must be maintained between the wall and the base or
back panel of the unit above.
The fitted cabinet must have a ventilation opening of 38 3/4 in² on the front. To
achieve this, cut back the base panel or fit a ventilation grill.
Ventilation slots and intakes must not be covered.
The safe operation of this appliance can only be guaranteed if it has been
installed in accordance with these installation instructions.
The units into which the appliance is fitted must be heat-resistant up 194°F.
Note: There should be a gap above the oven.
INSTALLATION
Cabinet Requirements
Flush installation also requires:
Two side cleats to be attached inside the cabinet frame, recessed from the front
A 5/16” baseplate underneath the unit body.
INSTALLATION
MWO-24
MWO-30
MWO-24
MWO-30