Loading ...
Loading ...
Loading ...
13
Door Access - Vestibule
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
+
+
DOOR STRIKE
MAGLOCK
For DC Power:
Install a 1N4005
diode or equivalent
Use 18-22 AWG
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
Use 18-22 AWG
For DC Power:
Install a 1N4005
diode or equivalent
Power for Door Strike
(Not Provided)
NORMALLY OPEN
COMMON
NORMALLY CLOSED
COMMON
OR
PRIMARY RELAY
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
(provided) or equivalent
Auxiliary Relay follows the same wiring schedule
as the Primary Relay.
DOOR SENSOR
(SUPERVISED)
DOOR SENSOR
(NON-SUPERVISED)
OR
EOL (End of Line) Resistor
(1k ohm)
SUPERVISED (DOOR STATUS) 1
DOOR SENSOR
(SUPERVISED)
DOOR SENSOR
(NON-SUPERVISED)
OR
EOL (End of Line) Resistor
(1k ohm)
SUPERVISED (DOOR STATUS) 2
AUXILIARY RELAY
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
DO NOT INSTALL THE SYSTEM IN THE FAIL SECURE MODE
UNLESS PERMITTED BY THE LOCAL AUTHORITY HAVING
JURISDICTION. Doing so may cause interference with the
operation of panic hardware.
NOTE: For UL
installations, only UL
294 Listed electric
door strikes or UL
294 Listed maglocks
may be connected to
relay output 1 or 2.
Loading ...
Loading ...
Loading ...