Loading ...
Loading ...
Loading ...
11
Gate Access
INTRODUCTION PRE-INSTALL NETWORKINSTALL ACCESS CONTROL
INPUTOUTPUT WIEGAND
GATE
SDA SCL
OUTPUT
NO COM NC NO COM NC
1 2
D1 COM D0 D1 COM D0
1 2
WIEGAND
1 GND 2
INPUT
GND 12V-24V
POWER
POWER ETHERNET
GATE OPERATOR
(connect to Aux
Closed Limit switch -
refer to gate operator
manual)
EOL (End of Line)
Resistor (1k ohm)
STATUS
+
MAGLOCK
Use 18-22 AWG
Power for Maglock
(Not Provided)
DO NOT use the power
supply for the controller
COMMON
NORMALLY CLOSED
NORMALLY CLOSED
COMMON
*AUXILIARY RELAY
NORMALLY OPEN
ALARM BYPASS
LIGHT
NORMALLY OPEN
COMMON
LOAD
LINE
AUXILIARY RELAY
OR
OR
NEUTRAL
Isolation
Relay
Low
Voltage
Power
Supply
PRIMARY RELAY
GATE OPERATOR
EXIT
NORMALLY OPEN
COMMON
For DC Power:
Install a 1N4005
diode or equivalent
For AC Power:
Install a Siemens S10K30MOV
(Metal Oxide Varistor) (provided)
or equivalent
NOTE: The SDA/SLA
Gate input/output shall
not be connected in UL
applications.
Not responsible for conflicts between the information listed in
the wiring diagram and the requirements of your local building
codes. The information is for suggested use ONLY. Check your
local codes BEFORE installation.
NOTE: For UL installations, only
UL 325 Listed gate operators, UL
294 Listed electric door strikes or
UL 294 Listed maglocks may be
connected to relay output 1 or 2.
Loading ...
Loading ...