Please check the following before calling for service:
1. Place one cup of water in a g ass measuring cup in the oven and close the door securely.
Operate the oven for two minutes at HIGH 100%.
A. Does the oven light come on? YES NO
B. Does the cooling fan work? YES NO
(Put your hand over the rear ventilating openings.)
C Does the turntable rotate? YES NO
It is normal for the turntable to turn in either direction.
D. Is the water in the over_ hot? YES NO
2. Remove water from the oven and operate the oven for 5 minutes at CONV 450°F.
A. Do CONV and COOK indicators light? YES NO
B. After the oven shuts off. is inside of the oven hot? YES NO
If "NO" is t he answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker.
If both are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER. A
microwave oven should never be serviced by a "do-it-yourself" repair person.
NOTE: If time appeanng in the display Jscounting down very rapidly, check Demonstration Mode on page 25
and cancel.
. . . - .
AC Line Voltage:
AC Power Required:
Output Power:
Microwave
Convection Heater
Frequency:
Outside Dimensions:
Cavity Dimensions _*'
Oven Capacity w_:
Cooking Uniformity:
Weight:
Single phase 120V, 60Hz. AC only
1.55 kW 13.0A (Microwave)
1.55 kW 13.0A (Convection)
900W*(IEC Test Procedure)
1450W
2450 MHz
R-930AK/AW: 24 %"(W) x 14 7/8"(H) x 19 1/8"(D)
R-930CS : 24 5&"(W) x 14 7/8"(H) x 19"(D)
16 1/8"(W) X 9 %"(H) x 16 1/8"(D)
1.5 cft
Turntable system, 15 3&,,diameter
Approx. 60 Ibs.
The International Electrotechnical Commission's standardized method for measuring output wattage. This
test method is widely recognized.
*w Internal capacity is calculated by measuring maximum width, depth and height. Actua capacity for
holding food is tess.
In compliance with standards set by:
FCC - Federal Communications Commission Authorized.
DHHS - Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21. Chapter I,
Subchapter J.
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.