Napoleon GDIZCNSB Inspiration ZC Series Direct Vent Natural Gas Fireplace

User Manual - Page 7

For GDIZCNSB.

PDF File Manual, 68 pages, Read Online | Download pdf file

GDIZCNSB photo
Loading ...
Loading ...
Loading ...
W415-1366 / A / 04.06.17
7
EN
2.4 GENERAL INFORMATION
FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND
QUALITY!
GDIZC
NG P
Altitude (FT) 0-4,500 0-4,500
Max. Input (BTU/HR) 24,000 24,000
Max. Output (BTU/HR) 20,400 20,400
Efficiency (w/the fan on) 85% 85%
A.F.U.E. (maximum value) 79% 79%
Min. Inlet Gas Supply Pressure 4.5" (11mb) Water Column 11" (27mb) Water Column
Max. Inlet Gas Supply Pressure 13" (32mb) Water Column 13" (32mb) Water Column
Manifold Pressure (Under Flow Conditions) 3.5" (9mb) Water Column 10" (25mb) Water Column
When the appliance is installed at elevations above 4,500ft (1372m), and in the absence of specific
recommendations from the local authority having jurisdiction, the certified high altitude input rating shall be
reduced at the rate of 4% for each additional 1,000ft (305m). Expansion
/ contraction noises during heating up and cooling down cycles are
normal and to be expected.
This appliance is not approved for closet or recessed installations. It
is approved for bathroom, bedroom and bed-sitting room installations
and is suitable for mobile homes. The natural gas model is suitable for
installation in a mobile home that is permanently positioned on its site
and fuelled with natural gas.
A barrier designed to reduce the risk of burns from the hot viewing glass is provided with the
appliance and must be installed.
65.5%