VFC Vent Free Fireplace System
GETTING STARTED
Make sure you have received all parts:
Check your packing list to verify that all listed parts have
been received. You should have the following:
Unvented gas heater
Installation/operating instruction
Four (4) black screws
Canopy and three (3) screws
Two (2) anchoring screws
Refractory cement logs or glass media
Carefully inspect the contents for shipping damage. If any
parts are missing or damaged, immediately inform the
dealer from whom you purchased the appliance. Do not
attempt to install any part of the appliance unless you
have all parts in good condition.
WHAT YOU WILL NEED FOR INSTALLATION:
You must have the following items available before pro-
ceeding with installation:
External regulator (for propane/LPG only)
Manual shutoff valve
Piping which complies with local codes
Sediment trap
Phillips head screwdriver
Tee joint
Pipe sealant approved for use with propane/LPG
Pipe wrench (resistant to sulfur compounds)
When planning the installation for the replace it is nec-
essary to determine where the unit is to be installed and
whether optional accessories are desired. Gas supply
piping should also be planned. The following steps repre-
sent the normal sequence of installation. Each installation
is unique, however, and might require a different sequence.
1. Position fireplace in desired location. Refer to the
Location of Fireplace and Clearances and Height
Requirements, and Firebox Framing sections found in
this manual.
PRE-INSTALLATION INFORMATION
Gloves are recommended when handling
refractory cement logs to prevent skin
irritation from loose bers. Logs are fragile
— handle with care.
WARNING:
WARNING—Do not install the heater:
Where curtains, furniture, clothing, or
other ammable objects are less than
42" from the front of the heater.
In high traf c areas.
In windy or drafty areas.
WARNING: If the area in which the heater
is operated does not meet the required
volume for indoor combustion air, combustion
and ventilation air shall be provided by one of
the methods described in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54, the International
Fuel Gas Code or applicable local codes.
NOTE: Be sure all packing material has been removed
from underside the unit.
2. Install canopy and logs per instructions found in this
manual. The canopy MUST be installed for safe oper-
ation of the unit.
3. Field wire main power supply to units with fan kit. Refer
to the Electrical Section found in this manual. (Electrical
connections should only be performed by an experi-
enced, licensed certi ed tradesman).
4. Install optional ON/OFF kit on units with millivolt control.
Refer to the installation instructions included with the
kit and also refer to the Electrical Wiring section found
in this manual.
5. Plumb gas line. Refer to the Connecting the Gas
section found in this
manual. (Gas connections should only be performed
by an experienced,
licensed/certi ed tradesman).
6. Complete nish wall material and/or surround.
ADEQUATE COMBUSTION AND VENTILA-
TION AIR
This heater shall not be installed in a con ned space or
unusually tight construction unless provisions are provided
for adequate combustion and ventilation air.
The National Fuel Gas Code, (ANSI Z223.1/NFPA54),
de nes a con ned space as a space whose volume is less
than 50 cubic feet per 1,000 BTU per hour (4.8m
3
per kw) of
the aggregate input rating of all appliances installed in that
pace, and an uncon ned space as a space whose volume
is not less than 50 cubic feet per 1,000 BTU per hour (4.8
m
3
per kw) of the aggregate input rating of all appliances
installed in that space. Rooms communicating directly with