FEEDER CABLE SECTION “Type H05RR-F or “H05V2V2-F (resistance to
temperatures of 90°C)”
220-240 V ac (V 2 ac) 3 x 2,5 mm
2
(*) (**)
380-415 V 2N ac 4 x 1,5 mm
2
(*)
380-415 V 3N ac 5 x 1,5 mm
2
(*)
(*) Connection with wall box connection.
(**) Diversity factor applied. A diversity factor may be applied to the total loading of the
appliance only by a suitably qualied person.
FEEDER CABLE SECTION “Type H05RR-F, H07RN-F or H05V2V2-F
(resistance to temperatures of 90°C)”
220-240 V ac (V 2 ac) 3 x 2,5 mm
2
(*) (**) or 3 x 4 mm
2
(*) or 5 x 1,5 mm
2
(*)
380-415 V 2N ac 5 x 1,5 mm
2
(*) (***), some models only
380-415 V 3N ac 5 x 1,5 mm
2
(*) (***), some models only
(*) Connection with wall box connection.
(**) Diversity factor applied. A diversity factor may be applied to the total loading of the
appliance only by a suitably qualied person.
(***) See also “MODELS SUPPLIED WITH POWER CORD 5x1,5 mm
2
ALREADY FITTED
TO THE APPLIANCE”
MODELS SUPPLIED WITHOUT POWER CORD
ALREADY FITTED TO THE APPLIANCE
MODELS SUPPLIED WITH POWER CORD
ALREADY FITTED TO THE APPLIANCE
CONNECTION OF THE POWER SUPPLY CABLE
Important! This cooktop must be connected to the electricity supply only by an
authorised person.
To connect the feeder cable to the hob it is necessary to carry out the following operations:
Unhook the terminal board cover “A” by inserting a screwdriver into the two hooks “B
(g. 2.1). Open completely the terminal block cover “A”.
Unscrew the screw C”, then unhook the cable clamp “D” by inserting a screwdriver
into the hook “E”. Remove completely the cable clamp “D” (g. 2.1).
Connect the phase, neutral and earth wires to terminal board “F” according to the
diagrams in g. 2.2; the U bolts G” (g. 2.1) shall be used as indicated in the diagrams
in g. 2.2 (they are supplied already tted to the terminals or inside the terminal board,
behind the cover).
Strain the feeder cable and block it with cable clamp “D” (by hooking hook “E” and
screwing screw “C”).
Close the cover “A” of the terminal board “F” (check the two hooks “B” are correctly hooked).
NOTE: The earth conductor must be left about 3 cm longer than the others.
The operations must be executed by a qualied technician.