FITTING REQUIREMENTS
This cooktop can be built into a working surface from 20 mm thick and 600 mm deep.
In order to install the ceramic hob into the kitchen xture, a hole with the dimensions shown
in gures 1.1a and 1.1b has to be made, keeping in consideration the following:
A 20 mm ventilation gap must be provided between the bottom of the appliance and any
cabinetry, draw unit or oven (g. 1.3).
If the cooktop is installed above an oven, the oven shall be provided with cooling fan.
The two appliances should be connected to the electrical supply with independent
connections.
The ceramic hob must be kept no less than 50 mm away from any side wall
(from side
edge of cutout).
The rear wall must be at least 50 mm from the ceramic hob
(from rear edge of cutout).
There must be a distance of at least 650 mm between the hob and any wall cupboard
or extractor hood positioned immediately above (see g. 1.2).
Standard installation (not ush): Do not seal the cooktop into the benchtop with silicone
or glue; this makes future servicing di󰀩cult. Elba Appl. AUS Service Agent will not
cover the costs of removing the cooktop, or of damage caused by this removal.
The walls surrounding the cooktop must be made of heat-resistant material.
Do not install the appliance near inammable materials (eg. curtains).
min
20 mm
Fig. 1.3
650 mm
500 mm
450 mm
Fig. 1.2
50 mm minimum
between the side of the
cut-out and the side wall