41
PERFORMANCE DATA SHEET
Water Filtration System
Model P9WB2L/P9RFWB2L/EDR2RXD1 Capacity 200 Gallons (757 Liters)
This system has been tested according to NSF/ANSI Standards 42, 53, 401, and CSA B483.1 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specied in NSF/ANSI Standards 42, 53, 401, and CSA B483.1. This system has been tested according to Ministerial Decree
No 174, article 9 of legislative decree n 31 of 2001, Regulations (EC) no 1935/2004, WRAS BS6920 and ACS Circulaire 2002/571.
Substance Reduction Aesthetic Effects Inuent Challenge Concentration Maximum Permissible
Product Water Concentration
Average% Reduction
Chlorine Taste/Odor Particulate Class I* 2.0 mg/L ± 10% At least 10,000
particles/mL
50% reduction 85% reduction 97.2% 99.5%
Contaminant Reduction Inuent Challenge Concentration Maximum Permissible Product Water
Concentration
Average%Reduction
Lead: @ pH 6.5/ @ pH 8.5 0.15 mg/L ± 10% 0.010 mg/L >99.3% / 98.6%
Benzene 0.015 mg/L ± 10% 0.005 mg/L 96.0%
p - Dichlorobenzene 0.225 mg/L ± 10% 0.075 mg/L >99.8%
Carbofuran 0.08 mg/L ± 10% 0.040 mg/L 91.9%
Toxaphene 0.015 ± 10% 0.003 mg/L 93.3%
Atrazine 0.009 mg/L ± 10% 0.003 mg/L 92.4%
Asbestos 10
7
to 10
8
bers/L
††
99% >99%
Asbestos 50,000/L min. 99.95% >99.99%
Live Cyst
†
11 NTU ± 10% 0.5 NTU 99.0%
Lindane 0.002 ± 10% 0.0002 mg/L 98.9%
Tetrachloroethylene 0.015 mg/L ± 10% 0.005 mg/L >96.6%
O-Dichlorobenzene 1.8 mg/L ± 10% 0.60 mg/L >99.9%
Ethylbenzene 2.1 mg/L ± 10% 0.70 mg/L 99.4%
1,2,4-Trichlorobenzene 0.210 mg/L ± 10% 0.07 mg/L >99.8%
2,4 - D 0.210 mg/L ± 10% 0.07 mg/L 93.8%
Styrene 2.0 mg/L ± 10% 0.1 mg/L 99.8%
Toluene 3.0 mg/L ± 10% 1.0 mg/L 87.9%
Endrin 0.006 mg/L ± 10% 0.002 mg/L >96.6%
Atenolol 200 ± 20% 30 ng/L >95.9%
Trimethoprim 140 ± 20% 20 ng/L >96.9%
Linuron 140 ± 20% 20 ng/L >96.4%
Estrone 140 ± 20% 20 ng/L >97.0%
Nonylphenol 1400 ± 20% 200 ng/L >97.4%
Carbamazepine 1400 ± 20% 200 ng/L >97.9%
Phenytoin 200 ± 20% 30 ng/L 93.8%
Naproxen 140 ± 20% 20 ng/L 96.1%
Bisphenol A 2000 ± 20% 300 ng/L >99.2%
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.6 gpm (2.27 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to
22°C). Rated service capacity = 200 gallons (757 liters).
The compounds certied under NSF 401 have been deemed as “emerging compounds/incidental contaminants.” Emerging compounds/incidental
contaminants are those compounds that have been detected in drinking water supplies at trace levels. While occurring at only trace levels, these
compounds can affect the public acceptance/perception of drinking water quality.
n It is essential that operational, maintenance, and lter replacement
requirements be carried out for the product to perform as advertised.
Property damage can occur if all instructions are not followed.
n The disposable cartridge must be changed at least every 6 months.
n Use replacement lter P9RFWB2L, part #EDR2RXD1/EDR2RXD1B.
2015 suggested retail price of $49.99 U.S.A./$49.99 Canada. Prices
are subject to change without notice.
n The lter monitor system measures the amount of water that passes
through the lter and alerts you when it is time to replace the lter.
Refer to the “Using the Controls” or “Water Filtration System” section
(in the User Instructions or User Guide) to learn how to check the
water lter status.
n After changing the water lter, ush the water system. See “Water and
Ice Dispensers” or “Water Dispenser” in the User Instructions or User
Guide.
System tested and certied by NSF International against
NSF/ANSI Standard 42, Standard 53, Standard 401, and
CSA B483.1 for the reduction of contaminants specied on
the Performance Data Sheet.