Installation
*INSTALLATION*
20
Risk of damage due to high hu-
midity.
In environments with high humidity,
condensation can build up on ex-
ternal refrigeration appliance panels.
This condensate can cause corrosion
on external appliance panels.
Install the refrigeration appliance in a
dry and/or air-conditioned room with
sufficient ventilation.
After installation please make sure
that the appliance door(s) closes
(close) properly and the refrigeration
appliance is installed in accordance
with these installation instructions. It
is essential to comply with the spe-
cified ventilation cutout require-
ments.
Side-by-side combinations
Risk of damage due to condens-
ation on external appliance panels.
In environments with high humidity
and a lack of ventilation, condensa-
tion can build up on external appli-
ance panels, which can cause corro-
sion.
Do not place refrigeration appliances
directly next to or on top of one an-
other.
Your refrigeration appliance can be in-
stalled with another refrigeration appli-
ance next to it as it is equipped with in-
tegrated heaters in the side panels.
Each of the two refrigeration appliances
must be built into a separate housing
unit.
Climate range
This refrigeration appliance is designed
for use within specific ambient temper-
atures (climate range). Do not use in
ambient temperatures for which it is not
designed.
A lower ambient temperature leads to
the compressor switching off for longer
periods. This can cause the internal
temperature in the refrigeration appli-
ance to rise with the risk of food deteri-
orating and going off.
The climate range is stated on the data
plate in the interior cabinet of the refri-
geration appliance.
Climate range Ambient temper-
ature
SN +10to +32°C
N +16to +32°C
ST +16to +38°C
T +16to +43°C
A freezer from the SN climate range
can operate without any difficulties in
rooms with a cooler ambient temper-
ature (down to +5°C).