Restraining Device
Anchor Points
Connection
Gas
Point
150mm
650mm
Grill shutter
The following table shows the supply and operating pressures for various supplies.
Gas type Natural gas Universal LPG Propane
Supply pressure at inlet to appliance regulator
(if fitted)
1.13 (kPa)
Minimum
2.75* (kPa) 2.75* (kPa)
Operating pressure at
appliance test point
1.00 (kPa) 2.75 (kPa) 2.75 (kPa)
* If the regulator is placed upstream of the cooker inlet, as is normal for cookers operating on LPG, then the supply pressure
and operating pressure are the same. The following table shows the injector sizes for each burner.
The following table shows the injector sizes for each burner.
Injector Natural gas Universal LPG Propane
Low heat burner 1.00 mm 0.55 mm 0.62 mm
Medium heat burner 1.35 mm 0.70 mm 0.82 mm
High heat burner 1.60 mm 0.90 mm 0.95 mm
Intense heat wok burner 1.75 mm 1.00 mm 1.00 mm
Grill – main injector 1.50 mm 0.82 mm 0.82 mm
Oven – main injector 1.60 mm 0.82 mm 0.95 mm
Oven – bypass screw 0.73 mm 0.45 mm 0.45 mm
Checking pipe size
To work out a suitable pipe size for connection use the information in this table.
Gas Consumption (MJ/h)
Model Natural gas Universal LPG Propane
CFG503 58.1 45.7 56.5
CFG504 47 36.7 47.5
CFG513 60.2 48.2 58.3
CFG516 37.3 30.2 -
CFG517 49.1 39.2 49.3
CFG505 47 36.7 47.5
Operation on NG
The appliance regulator MUST be orientated so that the
pressure nipple is accessible
The arrow showing the direction of flow MUST be
pointed correctly
The regulator has a ½” BSP internal thread at the inlet and outlet.
Gas requirements
This appliance must be installed by an authorised person, according to all codes and regulations of:
AS/NZS 5601.1 (particular attention to clause 6.10.1 and figure 6.3 on page 97, and clause 6.10.1.11)
Local gas fitting regulations, municipal building codes and other statutory regulations.
The cookers come in three gas types:
Natural gas, Propane and Universal LPG. If the cooker is required to use ULPG, a conversion kit can be obtained by
contacting the Customer Care Centre for details. Before installation, check that the cooker is suitable for the gas supply by looking
at the data plate behind the bottom of the oven door.
installation
Chef 540 Upright Cooker INSTALLATION 21
1/2”B SP
Internal Thread
NG Regulator
Pressure test point
Also use information about the length
of the run, number of elbows, tees and
bends, the available service pressure
and the supply requirements. AS/NZS
5601.1 will help you with this matter.