Loading ...
Loading ...
Loading ...
English
OPERATION (FV-0511VQC1 only)
Panasonic ventilating fan
responds to:
(1) Motion sensor detectible
condition.
(2) Humidity sensor detectible
condition.
Stop
When motion is
detected, fan runs
90°
Remains running
until the delay time
has passed
Human
activity
The distance that motion
can be detected is limited
to 10 feet (3m).
The field of view of the
sensor is 90°.
Room temperature is
25°C (77°F).
Fan
activity
FEATURE
All the WhisperCeiling ventilating fans come with Pick-A-Flow
speed options. The Pick-A-Flow switch on the face of all
WhisperCeiling ventilating fans allow the option to choose
50 – 80 – 110 CFM for the FV-0511VQ1 or 110 – 130 – 150 CFM
for the FV-1115VQ1.
These fans can run with constant air volume depending upon
the needs of the owner.
Pick-A-Flow Feature
Pick-A-Flow
switch
Air volume(CFM) Factory setting
FV-0511VQ1
FV-1115VQ1
50
110
80
130
110 80 CFM
150 130 CFM
FV-0511VQC1 50 80 110 80 CFM
Optimum Ventilation Performance:
Duct length, elbows and other factors increase static pressure which can hinder the performance of most
ventilation fans. This fan utilizes Smart Flow microchip technology that monitors the static pressure in the
system and speeds up or slows down the rpm of the fan depending upon the amount of resistance within
the ducts. This feature allows the fan to perform as rated and avoid potential installation issues.
The WhisperCeiling ventilating fans are built using DC motor technology. The DC motor is 30% - 70%
more energy efficient than the AC motor.
Outstanding Energy Savings:
INSIDE
OUTSIDE
10 feet
(3m)
sensor
Motion sensor detectible
condition
The delay time is determined
by timer preset switch.
The unit continues running for
an adjustable duration
of 0.5 to 60 minutes, after
motion is no longer detected.
1. The product will run when environment humidity rise rapidly but not reach to the humidity setting,
and stop after delay preset time.
2. Humidity setting selector is stepless change between 30 %RH~80 % RH.
3. The humidity detected by sensor may differ from the value on your hygrometer.
4. The product may turn on and off cause by the unstable environment humidity, you can improve
it by adjusting the Humidity setting selector.