Installation Instructions
Connecting the Duct Work
WARNING
Do not use screws to attach the duct work to the hood
exhaust outlet. Use duct tape only. Screws may prevent
the damper flaps on the top of the hood from opening.
If installing the unit with a recirculating kit, skip to Final
Electrical Installation. Otherwise, install the duct work
between the hood exhaust and the previously installed
duct work. Attach the duct to the hood exhaust with duct
tape alone. Use sheet metal screws (not provided) and
duct tape on the remaining joints.
Final Electrical Installation
WARNING
To avoid electric shock or fire hazard, prior to con-
necting the electrical wiring to the hood, make sure
that power to the hood power supply line is turned
off at the circuit breaker panel or fuse box.
Improper connection of the hood electrical wiring
may create an electric shock or fire hazard and may
result in damage to the hood’s electrical system.
See page 3 for specifications.
Do not ground the hood to the neutral (white) power
supply wire. Connect the hood ground wire to a
separate, proper ground wire installed by a licensed
electrician.
Make sure all wire used is capable of handling the
total connected load. See page 3.
Connect the house power supply wires to the wires
coming out of the hood junction box, inside the chim-
ney:
1. Connect the white wire
from the hood to the
neutral (white) power
supply wire.
2. Connect the black wire
from the hood to the hot
(black) power supply
wire.
3. Connect the green
and yellow wire from
the hood to the house
ground (green) wire from
the junction box.
Final Chimney Assembly
WARNING
Be careful not to pinch the electrical wires while
assembling the chimney.
1. Remove the protective plastic covering from both
pieces of the chimney assembly. Do not remove the
protective tape strips from the inside of the chimney.
They protect the telescoping pieces from scratching
during installation.
2. Carefully slide both sections together so that only the
vents on the top section show.
3. Hold the chimney vertically with the vents up.
Chimney
Chimney
mounting
bracket
Vent
Duct work
Hood
House power
supply wires
Wires to blower
inside hood
chassis