Frigidaire FF75DISPC1 Gray 3/4 HP Corded Disposer

Use & Care - Page 10

For FF75DISPC1.

PDF File Manual, 15 pages, Read Online | Download pdf file

FF75DISPC1 photo
Loading ...
Loading ...
Loading ...
10
123
879
456
1. After turning o power
supply, unbolt two nuts
and remove end plate.
2. Using a flathead
screwdriver or needle nose
pliers, remove clip from strain
relief portion of the cord.
3. Using wire cutters, cut black
(or brown) wire and white (or
blue) wire near the connectors.
4. Pull cord strain relief out
of endbell. Cut green
ground wire near the cord
strain relief.
5. Insert metal strain relief
connector (not included)
into the endbell hole and
tighten the nut securely.
6. Strip the green, black, and
white insulation from last ½
of each wire.
7. Insert the power supply
cable, coming from the
wall junction box,
through the strain relief
connector. Tighten
connector.
8. Connect disposal wire leads
(black and blue) to
corresponding wire leads of
the power supply cable.
Green always connects to
green.
9. Setting the wires into
the endbell, replace the
end plate and tighten the
two bolts.
PERMANENT WIRE INSTALLATION
Loading ...
Loading ...
Loading ...