Installation – Mounting Height & Clearance
6
www.zephyronline.com
DUCTING
A minimum of 8” round ducting must be used to
maintainmaximumairowefciency.
Always use rigid type metal ducts only. Flexible
ductscouldrestrictairowbyupto50%.
Alsousecalculation(onpage5)tocomputetotal
available duct run when using elbows, transitions
and caps.
ALWAYS, when possible, reduce the number or
transitions and turns. If long duct run is required,
increase duct size.
If turns or transitions are required; install as far
away from hood duct output and as far apart,
between the two as possible.
Minimum mount height between range top to hood
bottom should be no less than 30”.
Maximum mount height should be no higher than
36”.
It is important to install the hood at the proper
mounting height. Hoods mounted too low could
resultinheatdamageandrehazard;whilehoods
mounted too high will be hard to reach and will
loseitsperformanceandefciency.
If available, also refer range manufacturer’s height
clearance requirements and recommended hood
mounting height above range.
AK8800Ax
Vertical Ducting:
8”roundminimum(dualblower)
Horizontal Ducting:
N/A
DAMAGE-SHIPMENT / INSTALLATION:
• Pleasefullyinspectunitfordamagebefore
installation.
• Iftheunitisdamagedinshipment,returnthe
unit to the store in which it was bought for
repair or replacement.
• Iftheunitisdamagedbythecustomer,repair
or replacement is the responsibility of the
customer.
• Iftheunitisdamagedbytheinstaller(ifother
thanthecustomer),repairofreplacementmust
be made by arrangement between customer
and installer.
Min 30" - Max 36"
36"