OPERATION (cont.)
Condensate Pump Kit (Optional Accessory)
The condensate pump kit is available to allow continuous unit operation and
eliminate the need for emptying the drain tank.
When the water collects to level A in the
pump reservoir, the condensate pump
automatically discharges the water.
Note: The compressor does not operate while the condensate pump is
discharging the water out from the reservoir.
When the water level drops below level B, the condensate pump stops, and the
compressor restarts.
Note:
If for any reason the water level exceeds that of level A in the pump reservoir,
an overflow drain switch stops the unit operation, and the LCD displays “AS”.
If the fan mode is set to AUTO, the entire unit (including fan operation) turns off
either due to the overflow drain switch or while the condensate pump is
discharging the water.
ILL00064-00
B
A
ILL00966-00
Condensate Pump
Condensate Pump Reservoir
Discharge Hose