Regency 911-202 - Maxitrol Hand Held Remote Control 1

USER GUIDE - Page 8

For 911-202.

PDF File Manual, 16 pages, Read Online | Download pdf file

911-202 photo
Loading ...
Loading ...
Loading ...
8 | GV60 user guide
user guide
Modes of Operation
Briefly pressing the SET button changes the mode of operation in the following order:
NOTE: Manual mode can also be reached by pressing either the (large flame) or (small
flame) button.
- Manual Mode
Manual flame height adjustment.
- Daytime Temperature Mode
(Appliance must be in standby mode; pilot ignited.)
The room temperature is measured and compared to the set temperature. The flame height
is then automatically adjusted to achieve the Daytime Set Temperature.
- Light/Dimmer Setting Mode
Turns light/dimmer ON and OFF and adjusts brightness.
(Not available on the LRI3E/HRI3E)
- Circulating Fan
Turns circulating fan ON and OFF and adjusts fan speed.
NOTE: to turn OFF fan press (small flame) until all 4 speed level bars disappear.
- Nighttime Setback Temperature Mode
(Appliance must be in standby mode; pilot ignited.)
The room temperature is measured and compared to the Nighttime Setback Temperature.
The flame height is then automatically adjusted to achieve the Nighttime Setback Tem-
perature.
Loading ...
Loading ...
Loading ...