Regency 911-202 - Maxitrol Hand Held Remote Control 1

USER GUIDE - Page 13

For 911-202.

PDF File Manual, 16 pages, Read Online | Download pdf file

911-202 photo
Loading ...
Loading ...
Loading ...
CGV60 user guide| 13
user guide
To Turn Off Gas Appliance
To Turn Off Gas Appliance
Automatic Shut Off
Press the OFF button on the remote to shut off the appliance
Place ON/OFF switch, located on the appliance in the (O) OFF position.
If service is to be performed—the power must be disconnected and the gas to the unit must
be shut off.
6 Hour no Communication Function
(CSA version)
Manual Mode/Temperature/Timer Mode: the valve will turn to pilot flame if there is no
change in flame height for a 6 hour period. In Temperature/Timer Mode if the ambient room
temperature changes, the flame height will adjust automatically to maintain set tempera-
ture, and the fire will continue to function normally. The valve will turn to pilot flame if the set
temperature and the ambient room temperature remain the same over a 6 hour period.
Receiver Overheating
(Only if module is connected)
Valve turns to pilot flame if the temperature in the receiver is higher than 140ºF /(60ºC). the
main burner comes back on only when the temperature is below 40ºF/ (60ºC).
Low Battery Receiver
With low battery power in the receiver the system shuts off the fire completely. This will not hap-
pen if the power supply is interrupted.
Five Day Shut Off
(CSA version)
The system shuts off the fire completely if there is no change in flame height for 5 days.
Loading ...
Loading ...
Loading ...