6
installation manual
6. OUTDOOR UNIT IN ALLATION
Outdoor Unit Installation Instructions
Step 1: Select installation location.
The outdoor unit should be installed in the location that
meets the following requirements:
Place the outdoor unit as close to the indoor unit as
possible.
Ensure that the re is enough room for installation and
maintenance.
The air inlet and outlet must not be obstructed or
exposed to strong wind.
Ensure the location of the unit will not be subject to
snowdrifts, accumulation of leaves or other seasonal
debris. If possible, p rovide an awning for the unit.
Ensure the awning does not obstruct airflo w.
The installation a rea must be dry and well ventilated.
There must be enough room to install the connecting
pipes and cables and to access them for maintenance.
The area must be f ree of combustible gases and
chemicals.
The pipe length between the outdoor and indoor unit
may not exceed the maximum allowable pipe length.
If possible, DO NOT install the unit whe re it is
exposed to direct sunlight.
If possible, make su re the unit is located far away
from your neighbors’ p roperty so that the noise f rom
the unit will not disturb them.
If the location is exposed to st rong winds (for
example: near a seaside), the unit must be placed
against the wall to shelter it f rom the wind. If
necessary, use an awning. (See Fig. 6.1 & 6.2)
Install the indoor and outdoor units, cables and wi res
at least 1 meter f rom televisions or radios to p revent
static or image distortion. Depending on the radio
waves, a 1 meter distance may not be enough to
eliminate all interfe rence.
Strong wind
Strong wind
Strong wind
Fig. 6.1 Fig. 6.2
Step 2: Install outdoor unit.
Fix the outdoor unit with anchor bolts (M10)
>>60cm / 23.6
Fix with bolts
CAUTION
Be sure to remove any obstacles that
may block air ci rculation.
Make su re you refer to Length
Specifications to ensu re there is
enough room for installation and
maintenance.