Loading ...
Loading ...
Loading ...
Page 6 of 60
1.0 INTRODUCTION
1.1 SPECIFICATIONS
TABLE 1
ITEM
NATURAL GAS (NG)
PROPANE (LP)
INPUT: Hi
20,000 Btu/hr (5.861 kW)
19,500 Btu/hr (5.71 kW)
INPUT: Lo
13,000 Btu/hr (3.81 kW)
13,500 (3.96 kW)
MANIFOLD PRESSURE: Hi
COLLECTEUR DE PRESSION: FORT
3.5” w.c. (0.87 kPa)
10.0” w.c. (2.49 kPa)
MANIFOLD PRESSURE: Lo
COLLECTEUR DE PRESSION:
FAIBLE
1.7” w.c. (0.42 kPa)
6.4” w.c. (1.59 kPa)
GAS INLET SUPPLY PRESSURE:
ENTREE DE PRESSION
Minimum: 5.0” w.c. (1.2 kPa)
Minimum: 7.0” w.c. (1.74 kPa)
Maximum: 13.5” w.c. (3.4 kPa)
Maximum: 13.5 w.c. (3.4 kPa)
ORIFICE SIZE: @ 0-2000
FORMAT D'ORIFICE:
# 44 DMS
#56 DIMS
VALVE ORIFICE @ 0-2000
SOUPANGE D’ORIFICE:
# 51 DMS
#60 DIMS
AIR SHUTTER
VOLET DE L’AIR
OPEN 1/8”min
(3.175mm)
FULLY OPEN
CONTROL VALVE TYPE:
TYPE DE SOUPAPE
Skytech AF-40004
Robertshaw
Skytech AF-40004
Robertshaw
VENTING
ÉVACUATION
2-ply aluminum vent, Selkirk,
Duravent, Metal-Fab, ICC or Security
Venting
2-ply aluminum vent, Selkirk
Duravent, Metal-Fab, ICC or Security
Venting
FAN
VENTILATEUR
Variable Speed (115 Volt)
Variable Speed (115 Volt)
THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING
PLATE.
CET APPAREIL DOIT ÊTRE UTILISÉ UNIQUEMENT AVEC LE TYPE DE GAZ INDIQUÉ SUR LA
PLAQUE SIGNALÉTIQUE.
THIS APPLIANCE IS CERTIFIED FOR USE IN A BEDROOM / BATHROOM APPLICATION
CET APPAREIL EST CERTIFIÉ POUR UTILISATION DANS UNE APPLICATION CHAMBRE /
SALLE DE BAIN