Loading ...
Loading ...
Loading ...
9
ASSEMBLY INSTRUCTIONS
Hardware Used
EE
II
9
10
9. Support heater. Slide three washers washer Φ8 (EE )
over threaded end of spacer. Locate reflector assembly
on 3 spacers. Install three washers Φ8 on spacers and
securely tighten wing nuts (II) but do not overtighten.
10. Connect hose and regulator to cylinder.
The propane gas and cylinder are sold separately.
Use a standard 20 lb. propane cylinder only.
Use this heater only with a propane vapor withdrawal
supply system. See chapter 5 of the standard for
storage and handling of liquefied petroleum gas,
ANS/ NFPA 58. Your local library or fire department
should have this book.
A minimum supply pressure of 0.4 p.s.i. is required for
the purpose of input adjustment for propane gas. Storage
of an appliance indoors is permissible only if the cylinder
is disconnected and removed from the appliance. A
cylinder must be stored outdoors in a well-ventilated
area out of the reach of children. A disconnected cylinder
must have dust caps tightly installed and must not be
stored in a building, garage or any other enclosed area.
The minimum permissible gas supply pressure of 10
W.C. is required for purpose of input adjustment.
The minimum hourly of 17000 Btu is required input
rating for a heater for automatic operation at ratings less
than full input rating.
The pressure regulator and hose assembly supplied
with the appliance must be used.
The installation must conform with local codes, or in the
absence of local codes,with national fuel gas code,
ANS Z223.1/NFPA54, natural gas and propane
Installation Code, CSA B149.1, or propane storage and
handling code, B149.2.
x 6
Washer Φ8
Standard 20 lb. tank
x 3
Wing nut
II